5B Murray Street Kangaroo Valley NSW 2577
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 5,000 litre rainwater tank.
Key features
- Windows
- Up to aluminium frames 36.5 m², timber frames 8.4 m², single glazing 44.9 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by K.n.k Builders.
BASIX certificate
- Energy score
- 63 (target 63)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -17
- Heating load
- 105 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 182.5 m²
- Unconditioned floor area
- 16.1 m²
- Site area
- 991 m²
- Roof area
- 206 m²
- Garden area
- 698 m²
- Climate zone
- NatHERS climate zone 24
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 36.5 m², timber frames 8.4 m², single glazing 44.9 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: light steel frame (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: light steel frame. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: light steel frame (not specified)
- Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1777417S_03, issued 4 July 2025, from the council's DA documents.
Other certificates for this address
BASIX certificate, certificate 1777417S_02, issued 18 February 2025
BASIX certificate
- Energy score
- 63 (target 63)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -2
- Heating load
- 105 MJ/m² a year
- Cooling load
- 17 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 182.5 m²
- Unconditioned floor area
- 16.1 m²
- Site area
- 991 m²
- Roof area
- 206 m²
- Garden area
- 698 m²
- Climate zone
- NatHERS climate zone 24
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 36.5 m², timber frames 8.4 m², single glazing 44.9 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1777417S_02, issued 18 February 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.