5 Beecroft Parade Currarong NSW 2540

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.4 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 3,500 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 87 against 69 for energy and 42 against 40 for water.

Key features

Windows
18 windows and glazed doors: 100 SERIES - ALUMINIUM SLIDING WINDOW SG 4Clr; 100 Series Awning Window SG 4Clr
Wall insulation
R2.0
Roof and ceiling insulation
Ceiling R4.5, roof SlabExt:Slab - Suspended Slab - External Insul : 200mm: 200mm Suspended Slab - External Insul 1.0, light colour
Hot water
Electric boosted solar with a performance of 26 to 30 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
87 (target 69)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
39 MJ/m² a year
Cooling load
20 MJ/m² a year
Bedrooms
4
Conditioned floor area
375.5 m²
Unconditioned floor area
16.6 m²
Site area
695 m²
Roof area
367 m²
Garden area
5 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric boosted solar with a performance of 26 to 30 STCs or better
Solar panels
3 kW
Rainwater tank
3,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 109.8 m², single glazing 109.8 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood. all external walls polystyrene
  • External garage wall: AAC veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: polystyrene; roof: foil/sarking.)

Certificate 1784280S_03, issued 31 March 2026, from the council's DA documents.

NatHERS certificate

Star rating
7.4 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
11 Feb 2025
Wall insulation
R2.0
Ceiling insulation
R4.5
Floor insulation
R2.0
Living room glazing by direction
NE 5.6 m², SW 4.7 m², NW 21.2 m²
All glazing by direction
NE 16.4 m², SE 5 m², SW 16.7 m², NW 32.4 m²

Roof

  • SlabExt:Slab - Suspended Slab - External Insul : 200mm: 200mm Suspended Slab - External Insul 1.0, light colour
  • GreenRoofIntensive:Slab - 500mm Substrate : 200mm:200mm Slab - 500mm Substrate 1.5, light colour

Window types

  • SSW-001-07 A 100 SERIES - ALUMINIUM SLIDING WINDOW SG 4Clr: U-value 6.16, SHGC 0.74
  • SSW-010-01 A 100 Series Awning Window SG 4Clr: U-value 6.23, SHGC 0.66

Window schedule

  • garage, window SSW-001-07 A: 1,200 × 1,600 mm facing SW
  • garage, window SSW-001-07 A: 1,200 × 1,600 mm facing SW
  • pdr & shr, window SSW-010-01 A: 1,200 × 600 mm facing NE
  • kitchen/dining - roof, window SSW-001-07 A: 2,340 × 2,400 mm facing NE
  • kitchen/dining - roof, window SSW-001-07 A: 2,340 × 6,200 mm facing NW
  • kitchen/dining - roof, window SSW-001-07 A: 2,340 × 2,000 mm facing SW
  • kitchen/dining - roof, window SSW-001-07 A: 1,275 × 5,230 mm facing NW
  • master bed, window SSW-001-07 A: 1,200 × 2,400 mm facing SW
  • ens, window SSW-001-07 A: 2,675 × 4,200 mm facing NW
  • ens, window SSW-001-07 A: 1,200 × 1,200 mm facing SW
  • plant, window SSW-001-07 A: 1,200 × 4,200 mm facing SE
  • hall, window SSW-001-07 A: 1,200 × 3,200 mm facing SW
  • bed 1, window SSW-001-07 A: 1,200 × 1,600 mm facing NE
  • ens - bed 1, window SSW-001-07 A: 1,200 × 1,200 mm facing NE
  • ens - bed 2, window SSW-001-07 A: 1,200 × 1,200 mm facing NE
  • bed 2, window SSW-001-07 A: 1,200 × 1,600 mm facing NE
  • bed 3, window SSW-001-07 A: 1,200 × 1,600 mm facing NE
  • ens - bed 3, window SSW-001-07 A: 1,200 × 1,200 mm facing NE

Certificate NCW23UT044, issued 11 February 2025, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1784280S_02, issued 17 August 2025

BASIX certificate

Energy score
90 (target 69)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
26 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
4
Conditioned floor area
337.7 m²
Unconditioned floor area
56.8 m²
Site area
695 m²
Roof area
367 m²
Garden area
5 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric boosted solar with a performance of 26 to 30 STCs or better
Solar panels
3 kW
Rainwater tank
3,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 70.6 m², double glazing 70.6 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood. all external walls polystyrene
  • External garage wall: AAC veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: polystyrene; roof: foil/sarking.)

Certificate 1784280S_02, issued 17 August 2025, from the council's DA documents.

BASIX certificate, certificate 1784280S, issued 20 February 2025

BASIX certificate

Energy score
88 (target 69)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
48 MJ/m² a year
Cooling load
10 MJ/m² a year
Bedrooms
4
Conditioned floor area
336.1 m²
Unconditioned floor area
56.8 m²
Site area
695 m²
Roof area
442 m²
Garden area
5 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric boosted solar with a performance of 26 to 30 STCs or better
Solar panels
3 kW
Rainwater tank
3,500 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 70.6 m², double glazing 70.6 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (no added insulation)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: AAC veneer; frame: timber - untreated softwood. all external walls polystyrene
  • External garage wall: AAC veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, no frame (ceiling: polystyrene; roof: foil/sarking.)

Certificate 1784280S, issued 20 February 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related