Skip to main content

41 Island Point Road St Georges Basin NSW 2540

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 5 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 98 against 69 for energy and 53 against 40 for water.

Key features

Windows
Up to aluminium frames 84.9 m², double glazing 84.9 m²
Wall insulation
Not specified
Roof and ceiling insulation
Ceiling: not specified; roof: not specified
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
98 (target 69)
Water score
53 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
39 MJ/m² a year
Cooling load
21 MJ/m² a year
Bedrooms
5
Conditioned floor area
308.5 m²
Unconditioned floor area
170.5 m²
Site area
2,732 m²
Roof area
521 m²
Garden area
100 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
5 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
aluminium frames 84.9 m², double glazing 84.9 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (not specified)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (not specified)
  • Garage floor: concrete slab on ground, waffle pod slab (not specified)
  • External wall: brick veneer; frame: timber - untreated softwood (not specified)
  • External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (not specified)
  • External garage wall: brick veneer; frame: timber - untreated softwood (not specified)
  • External garage wall: concrete block/plasterboard; frame: no frame (not specified)
  • Internal wall: plasterboard; frame: timber - untreated softwood (not specified)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: not specified; roof: not specified.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - untreated softwood (ceiling: not specified; roof: not specified.)

Certificate 1777229S, issued 11 December 2024, from the council's DA documents.