Skip to main content

4 Mitchell Road Callala Bay NSW 2540

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,200 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX water target, scoring 48 against 40.

Key features

Windows
18 windows and glazed doors: Timber A SG Clear; Aluminium Awning Window SG 3Clr; Aluminium French Door SG 4Clr and 9 more types
Wall insulation
R2.7
Roof and ceiling insulation
Ceiling R4, R6, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Hotondo Southcoast.

BASIX certificate

Energy score
69 (target 69)
Water score
48 (target 40)
Thermal performance
Pass
Materials score
-21
Heating load
42 MJ/m² a year
Cooling load
19 MJ/m² a year
Bedrooms
4
Conditioned floor area
156 m²
Unconditioned floor area
10 m²
Site area
421 m²
Roof area
180 m²
Garden area
172 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Rainwater tank
2,200 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 36.4 m², single glazing 10.4 m², double glazing 26 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above open subfloor, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, AAC panel (75 mm); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1825915S, issued 10 December 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.2.6 (3.23)
Rated on
10 Dec 2025
Wall insulation
R2.7
Ceiling insulation
R4, R6
Floor insulation
R2.7, R2, R4
LED downlights
54
Living room glazing by direction
NE 2.5 m², SE 13.5 m², SW 6.8 m², NW 3.2 m²
All glazing by direction
NE 4.8 m², SE 14.9 m², SW 7.6 m², NW 8.9 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • DOW-002-001 Aluminium Awning Window SG 3Clr: U-value 6.4, SHGC 0.65
  • DOW-016-001 Aluminium French Door SG 4Clr: U-value 6.1, SHGC 0.62
  • DOW-001-015 Aluminium Sliding Window SG 4ETClr: U-value 4.5, SHGC 0.63
  • DOW-025-005 Thermally Broken Aluminium Sliding Door DG 4SolB/12Ar/4Clr: U-value 1.8, SHGC 0.19
  • DOW-005-010 Aluminium Awning Window DG LB GySI 6.38/10/4: U-value 3, SHGC 0.28
  • DOW-005-012 Aluminium Awning Window DG LB Clr 5/10/5: U-value 3, SHGC 0.44
  • DOW-002-015 Aluminium Awning Window SG 4ETClr: U-value 4.8, SHGC 0.55
  • DOW-021-002 Thermally Broken Aluminium Awning Window DG 4Clr/12Ar/4ET: U-value 1.9, SHGC 0.52
  • DOW-021-007 Thermally Broken Aluminium Awning Window DG 4SolB/12Ar/4Clr: U-value 1.7, SHGC 0.18
  • DOW-023-006 Thermally Broken Aluminium Fixed Window DG 4SolB/12Ar/4Clr: U-value 1.6, SHGC 0.2
  • DOW-017-007 Aluminium French Door DG LB ClrPrvSI 6.38/12/4: U-value 3.2, SHGC 0.33

Window schedule

  • BATH, window DOW-002-001: 300 × 900 mm facing NW
  • LDRY, window DOW-016-001: 2,100 × 900 mm facing NW
  • BED 2, window DOW-001-015: 1,000 × 1,450 mm facing NW
  • Bedroom 3, window DOW-001-015: 1,000 × 1,450 mm facing NE
  • Bedroom 4, window DOW-001-015: 1,000 × 1,450 mm facing SE
  • ENTRY, window TIM-001-01 W: 2,100 × 400 mm facing SW
  • Kitchen/Living, window DOW-025-005: 2,400 × 3,600 mm facing SE
  • Kitchen/Living, window DOW-005-010: 1,800 × 850 mm facing SE
  • Kitchen/Living, window DOW-005-010: 1,800 × 850 mm facing SW
  • Kitchen/Living, window DOW-005-010: 1,800 × 850 mm facing SW
  • Kitchen/Living, window DOW-005-010: 1,800 × 850 mm facing SW
  • Kitchen/Living, window DOW-005-012: 1,800 × 1,800 mm facing NW
  • MASTER, window DOW-002-015: 857 × 2,400 mm facing NW
  • ENS, window DOW-002-015: 600 × 1,450 mm facing NE
  • LIVING, window DOW-021-002: 1,200 × 2,050 mm facing NE
  • LIVING, window DOW-021-007: 857 × 2,050 mm facing SE
  • LIVING, window DOW-023-006: 1,800 × 850 mm facing SE
  • LIVING, window DOW-017-007: 2,400 × 900 mm facing SW

Certificate 0012607008, issued 10 December 2025, from the council's DA documents.