North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
30 Thomas Street Milton NSW 2538
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 1 kW of solar panels and a 2,300 litre rainwater tank. It beat its BASIX energy target, scoring 75 against 69.
Key features
- Windows
- Up to aluminium frames 65 m², timber frames 2.7 m², single glazing 2.7 m², double glazing 65 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 75 (target 69)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -33
- Heating load
- 46 MJ/m² a year
- Cooling load
- 15 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 170.7 m²
- Unconditioned floor area
- 12.7 m²
- Site area
- 569 m²
- Roof area
- 334 m²
- Garden area
- 225 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Solar panels
- 1 kW
- Rainwater tank
- 2,300 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 65 m², timber frames 2.7 m², single glazing 2.7 m², double glazing 65 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1774105S, issued 21 November 2024, from the council's DA documents.