2/-/DP1025939
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 1 kW of solar panels and an 80,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 75 against 69 for energy and 67 against 40 for water.
Key features
- Windows
- Up to aluminium frames 133.9 m², timber frames 3.8 m², double glazing 137.7 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 75 (target 69)
- Water score
- 67 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 34 MJ/m² a year
- Cooling load
- 26 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 340.6 m²
- Unconditioned floor area
- 20.7 m²
- Site area
- 20,000 m²
- Roof area
- 480 m²
- Garden area
- 2,000 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Solar panels
- 1 kW
- Rainwater tank
- 80,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 133.9 m², timber frames 3.8 m², double glazing 137.7 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1782457S, issued 6 February 2025, from the council's DA documents.