Skip to main content

2/-/DP1025939

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 1 kW of solar panels and an 80,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 75 against 69 for energy and 67 against 40 for water.

Key features

Windows
Up to aluminium frames 133.9 m², timber frames 3.8 m², double glazing 137.7 m²
Wall insulation
Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
75 (target 69)
Water score
67 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
34 MJ/m² a year
Cooling load
26 MJ/m² a year
Bedrooms
4
Conditioned floor area
340.6 m²
Unconditioned floor area
20.7 m²
Site area
20,000 m²
Roof area
480 m²
Garden area
2,000 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Solar panels
1 kW
Rainwater tank
80,000 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 133.9 m², timber frames 3.8 m², double glazing 137.7 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1782457S, issued 6 February 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.