This home has a NatHERS rating of 7.2 stars out of 10. Its BASIX certificate commits it to 10 kW of solar panels and a 5,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 100 against 69 for energy and 42 against 40 for water.
Key features
- Windows
- 23 windows and glazed doors: Trend Thermal Awning Window DG 3/19/3; Trend Thermal Sliding Door DG 3/19/3; Trend Al Bi-Fold Door DG LightBridge_ClrSI_638-8-4
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R6.0, roof Cont:Attic-Continuous 1.3, light colour
- Hot water
- Electric heat pump
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area)
BASIX certificate
- Energy score
- 100 (target 69)
- Water score
- 42 (target 40)
- Thermal performance
- Pass
- Materials score
- 3
- Heating load
- 39 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 240 m²
- Unconditioned floor area
- 39 m²
- Site area
- 712 m²
- Roof area
- 269 m²
- Garden area
- 100 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric heat pump
- Solar panels
- 10 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 34 m², double glazing 34 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 7 star (cold zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 7 star (cold zone)
Construction and insulation
- Floor: concrete slab on ground (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: framed (fibre cement sheet or boards); frame: please select (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1732850S, issued 19 January 2024, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.2 stars
- Rated with
- FirstRate5: 5.5.4 (3.22)
- Rated on
- 18 Jan 2024
- Wall insulation
- R2.5
- Ceiling insulation
- R6.0
- Floor insulation
- R2.5, R0.6
- Living room glazing by direction
- N 17.5 m², S 2.2 m², W 7.8 m²
- All glazing by direction
- N 23.2 m², E 10.9 m², S 4.7 m², W 7.8 m²
Roof
- Cont:Attic-Continuous 1.3, light colour
Window types
- TND-050-01 W Trend Thermal Awning Window DG 3/19/3: U-value 3.32, SHGC 0.53
- TND-053-01 W Trend Thermal Sliding Door DG 3/19/3: U-value 3.4, SHGC 0.65
- TND-026-07 A Trend Al Bi-Fold Door DG LightBridge_ClrSI_638-8-4: U-value 3.38, SHGC 0.38
Window schedule
- Bed 4, window TND-050-01 W: 1,500 × 2,110 mm facing E
- Bed 3, window TND-050-01 W: 1,030 × 1,510 mm facing S
- Ground Bath, window TND-050-01 W: 600 × 910 mm facing N
- Lounge, window TND-053-01 W: 2,040 × 2,000 mm facing N
- Lounge, window TND-050-01 W: 600 × 2,110 mm facing W
- Lounge, window TND-050-01 W: 600 × 2,110 mm facing S
- Bed 1, window TND-050-01 W: 1,500 × 2,400 mm facing E
- Bed 1, window TND-050-01 W: 1,500 × 800 mm facing E
- Bed 1, window TND-050-01 W: 1,500 × 1,510 mm facing N
- Bed 2, window TND-050-01 W: 1,370 × 2,110 mm facing N
- Bed 2, window TND-050-01 W: 1,370 × 2,110 mm facing E
- Kit/Din, window TND-050-01 W: 900 × 910 mm facing W
- Kit/Din, window TND-050-01 W: 1,500 × 700 mm facing N
- Kit/Din, window TND-050-01 W: 1,500 × 700 mm facing N
- Kit/Din, window TND-050-01 W: 1,500 × 700 mm facing N
- Kit/Din, window TND-050-01 W: 1,500 × 700 mm facing N
- Kit/Din, window TND-050-01 W: 600 × 1,510 mm facing S
- Kit/Din, window TND-050-01 W: 1,370 × 2,110 mm facing N
- Kit/Din, window TND-050-01 W: 1,370 × 2,110 mm facing N
- Kit/Din, window TND-053-01 W: 2,100 × 2,700 mm facing W
- Kit/Din, window TND-026-07 A: 1,100 × 2,200 mm facing N
- Kit/Din, window TND-050-01 W: 700 × 1,500 mm facing N
- First Bath, window TND-050-01 W: 600 × 1,510 mm facing S
Certificate PVTESYJFH0-01, issued 18 January 2024, from the council's DA documents. Verify this certificate