Skip to main content

15 The Palisade Manyana NSW 2539

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 3 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 100 against 69.

Key features

Windows
18 windows and glazed doors: Timber A SG Clear; Aluminium B DG Air Fill Clear-Clear; Aluminium B DG Argon Fill High Solar Gain low-E
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R5, roof Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by White Sands.

BASIX certificate

Energy score
100 (target 69)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-50
Heating load
49 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
3
Conditioned floor area
147 m²
Unconditioned floor area
13.7 m²
Site area
630 m²
Roof area
275 m²
Garden area
337 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Solar panels
3 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 34.5 m², timber frames 0.4 m², single glazing 0.4 m², double glazing 34.5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1765789S, issued 24 September 2024, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
24 Sep 2024
Wall insulation
R2.5
Ceiling insulation
R5
Floor insulation
R2.5, R2
LED downlights
27
Living room glazing by direction
N 4.3 m², E 10.2 m², S 7.5 m²
All glazing by direction
N 9.1 m², E 11.5 m², S 11.9 m², W 6.7 m²

Roof

  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, light colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • ALM-004-01 A Aluminium B DG Air Fill Clear-Clear: U-value 4.8, SHGC 0.59
  • ALM-006-03 A Aluminium B DG Argon Fill High Solar Gain low-E: U-value 4.1, SHGC 0.52

Window schedule

  • Foyer, window TIM-001-01 W: 1,600 × 250 mm facing N
  • Bed 1, window ALM-004-01 A: 1,460 × 2,170 mm facing N
  • Bed 1, window ALM-004-01 A: 2,040 × 610 mm facing N
  • Ens, window ALM-004-01 A: 600 × 2,170 mm facing E
  • Kitchen/Living 1, window ALM-006-03 A: 2,100 × 3,584 mm facing E
  • Kitchen/Living 1, window ALM-004-01 A: 1,460 × 900 mm facing E
  • Kitchen/Living 1, window ALM-004-01 A: 1,460 × 900 mm facing E
  • Kitchen/Living 1, window ALM-006-03 A: 2,100 × 3,588 mm facing S
  • Kitchen/Living 1 W11: 650 × 1,810 mm facing N
  • Kitchen/Living 1 W12: 650 × 1,810 mm facing N
  • Kitchen/Living 1 W13: 650 × 1,810 mm facing N
  • Kitchen/Living 1, window ALM-004-01 A: 500 × 1,570 mm facing N
  • Bed 2, window ALM-004-01 A: 1,200 × 1,810 mm facing S
  • Bed 3, window ALM-004-01 A: 1,200 × 1,810 mm facing S
  • Pwd, window ALM-004-01 A: 860 × 610 mm facing W
  • Bath, window ALM-004-01 A: 860 × 1,210 mm facing W
  • Laundry, window ALM-004-01 A: 2,100 × 1,450 mm facing W
  • Media, window ALM-004-01 A: 860 × 2,410 mm facing W

Certificate 0009771015, issued 24 September 2024, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.