Skip to main content

14 Palisade Court Kangaroo Valley NSW 2577

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 3 kW of solar panels and an 8,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 66 against 63 for energy and 42 against 40 for water.

Key features

Windows
Up to aluminium frames 196 m², single glazing 42 m², double glazing 154 m²
Wall insulation
All external walls fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

BASIX certificate

Energy score
66 (target 63)
Water score
42 (target 40)
Materials score
-73
Heating load
87 MJ/m² a year
Cooling load
35 MJ/m² a year
Bedrooms
4
Conditioned floor area
317 m²
Unconditioned floor area
9 m²
Site area
6,218 m²
Roof area
510 m²
Garden area
1,000 m²
Climate zone
NatHERS climate zone 24
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
3 kW
Rainwater tank
8,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 196 m², single glazing 42 m², double glazing 154 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0

Construction and insulation

  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (metal clad); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1765756S_02, issued 6 August 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1765756S, issued 24 September 2024

BASIX certificate

Thermal performance
Pass
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
3 kW
Rainwater tank
8,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0 v Vv
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0 v Vv

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0 v Vv
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 2.5 - 3.0 Vv v

Certificate 1765756S, issued 24 September 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?