132A River Road, Sussex Inlet Lot 72 DP 1135125

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 2.5 kW of solar panels and a 3,600 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 74 against 69 for energy and 48 against 40 for water.

Key features

Windows
31 windows and glazed doors: Timber A DG Air Fill Tint-Clear; Thermally Broken Aluminium Fixed Window DG 4OptiS3ProTClr/12Ar/4LoEi89; Thermally Broken Aluminium Sliding Window DG 4OptiS3ProTClr/12Ar/4LoEi89 and 7 more types
Wall insulation
R2.7
Roof and ceiling insulation
Ceiling R6, R3, R5, roof Waterproofing Membrane Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
74 (target 69)
Water score
48 (target 40)
Thermal performance
Pass
Materials score
-46
Heating load
37 MJ/m² a year
Cooling load
24 MJ/m² a year
Bedrooms
3
Conditioned floor area
203 m²
Unconditioned floor area
39 m²
Site area
670 m²
Roof area
193 m²
Garden area
253 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Solar panels
2.5 kW
Rainwater tank
3,600 litres
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 74 m², timber frames 3 m², single glazing 9 m², double glazing 68 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, 40% cement substitute, waffle pod slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, 40% cement substitute, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1776693S, issued 9 December 2024, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.2.3 (3.23)
Rated on
09 Dec 2024
Wall insulation
R2.7
Ceiling insulation
R6, R3, R5
Floor insulation
R2.7, R2, R3, R6, R2.5
LED downlights
68
Living room glazing by direction
N 10.6 m², E 18.5 m², S 4.3 m²
All glazing by direction
N 23.2 m², E 35.5 m², S 7.7 m², W 9.8 m²

Roof

  • Waterproofing Membrane Bulk, Reflective Side Down, No Air Gap Above R1.3, medium colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.3, dark colour

Window types

  • TIM-003-02 W Timber A DG Air Fill Tint-Clear: U-value 2.9, SHGC 0.33
  • STG-101-025 Thermally Broken Aluminium Fixed Window DG 4OptiS3ProTClr/12Ar/4LoEi89: U-value 1.5, SHGC 0.47
  • STG-104-016 Thermally Broken Aluminium Sliding Window DG 4OptiS3ProTClr/12Ar/4LoEi89: U-value 2, SHGC 0.47
  • STG-100-039 Thermally Broken Aluminium Fixed Window DG 4OptiS3ProTClr/12Ar/4LoEi89: U-value 1.4, SHGC 0.5
  • STG-072-013 Aluminium Double Hung Window DG 5Pb/12Ar/5Pb: U-value 3.5, SHGC 0.46
  • STG-108-023 Thermally Broken Aluminium Sliding Door DG 4OptiS3ProTClr/12Ar/4LoEi89: U-value 1.7, SHGC 0.47
  • STG-078-334 Aluminium Fixed Window DG 4optitherm/12Ar/4LoEi89: U-value 1.9, SHGC 0.51
  • STG-007-001 Aluminium Sliding Window SG 3Clr: U-value 6.3, SHGC 0.73
  • STG-088-300 Aluminium Hinged Door DG 4PbAS2/12Ar/4PbG: U-value 3.3, SHGC 0.4
  • STG-102-039 Thermally Broken Aluminium Awning Window DG 4OptiS3ProTClr/12Ar/4LoEi89: U-value 2, SHGC 0.4
  • STG-007-019 Aluminium Sliding Window SG 6ETGy: U-value 4.6, SHGC 0.41

Window schedule

  • Kitchen, window STG-101-025: 700 × 2,100 mm facing N
  • Kitchen, window STG-104-016: 700 × 2,100 mm facing E
  • Kitchen, window STG-100-039: 1,200 × 900 mm facing E
  • Kitchen, window STG-072-013: 1,200 × 900 mm facing E
  • Kitchen, window STG-108-023: 2,400 × 1,800 mm facing S
  • ENTRY, window STG-078-334: 1,457 × 2,400 mm facing E
  • ENTRY, window TIM-003-02 W: 2,400 × 1,200 mm facing W
  • ENTRY, window STG-100-039: 1,500 × 750 mm facing N
  • ENTRY, window STG-072-013: 1,500 × 750 mm facing N
  • DINING, window STG-108-023: 2,400 × 2,700 mm facing N
  • DINING, window STG-078-334: 1,457 × 2,400 mm facing E
  • DINING, window STG-078-334: 1,457 × 2,400 mm facing E
  • HALL, window STG-072-013: 1,500 × 600 mm facing S
  • Garage, window STG-007-001: 600 × 3,000 mm facing W
  • LDRY, window STG-088-300: 2,400 × 900 mm facing W
  • BATH 1, window STG-007-001: 900 × 1,800 mm facing S
  • Bedroom 1, window STG-108-023: 2,100 × 2,700 mm facing E
  • WIR, window STG-102-039: 1,500 × 600 mm facing S
  • ENS, window STG-007-019: 900 × 1,200 mm facing W
  • BATH, window STG-007-001: 900 × 1,200 mm facing W
  • WC, window STG-007-001: 900 × 900 mm facing W
  • Bedroom 3, window STG-108-023: 2,100 × 2,100 mm facing N
  • LANDING, window STG-108-023: 2,100 × 2,700 mm facing E
  • Bedroom 2, window STG-108-023: 2,100 × 2,100 mm facing N
  • Bedroom 2, window STG-072-013: 1,200 × 900 mm facing E
  • Bedroom 2, window STG-100-039: 1,200 × 900 mm facing E
  • ENTRY VOID, window STG-078-334: 1,000 × 1,500 mm facing N
  • DINING VOID, window STG-078-334: 1,457 × 1,800 mm facing N
  • DINING VOID, window STG-078-334: 1,457 × 2,400 mm facing E
  • LIVING, window STG-078-334: 1,457 × 2,400 mm facing E
  • LIVING, window STG-072-013: 1,457 × 600 mm facing E

Certificate 0011603354, issued 9 December 2024, from the council's DA documents.