North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
12 Tulip Street Hyams Beach NSW 2540
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 6 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 97 against 69 for energy and 42 against 40 for water.
Key features
- Windows
- Up to aluminium frames 85.9 m², single glazing 12.8 m², double glazing 73.1 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom); Wood heater (living area)
BASIX certificate
- Energy score
- 97 (target 69)
- Water score
- 42 (target 40)
- Thermal performance
- Pass
- Materials score
- -49
- Heating load
- 34 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 229.3 m²
- Unconditioned floor area
- 19.2 m²
- Site area
- 614 m²
- Roof area
- 264 m²
- Garden area
- 150 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Solar panels
- 6 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 85.9 m², single glazing 12.8 m², double glazing 73.1 m²
Heating
- Living area: wood heater; Energy rating: n/a
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 4 Star (old label)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 4 Star (old label)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 4 Star (old label)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: suspended floor above open subfloor, particle board; frame: laminated veneer lumber (LVL) (not specified)
- Floor: above habitable rooms or mezzanine, particle board; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
- Garage floor: concrete - suspended; frame: no frame (not specified)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, laminated veneer lumber (LVL) (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1756744S, issued 22 July 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.