Skip to main content

12 Malibu Drive Bawley Point NSW 2539

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 1 kW of solar panels and a 20,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 78 against 69 for energy and 63 against 40 for water.

Key features

Windows
72 windows and glazed doors: 52mm Altair Louvre Window System SG 6LE; TB Aluminium Sliding Window DG LightBridge_ClrS0_4-12-4; TB Al Fixed-DG with TPS Spacer LightBridge_ClrSI_6.38-10-4 and 4 more types
Wall insulation
R5.0, R1.0, R2.5
Roof and ceiling insulation
Ceiling R3.0, roof Metal deck uninsulated, medium colour
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area); 1-phase airconditioning, non ducted (bedroom)

Built by Skwarko Constructions.

BASIX certificate

Energy score
78 (target 69)
Water score
63 (target 40)
Thermal performance
Pass
Materials score
-76
Heating load
33 MJ/m² a year
Cooling load
27 MJ/m² a year
Bedrooms
4
Conditioned floor area
171.9 m²
Unconditioned floor area
34.5 m²
Site area
765 m²
Roof area
148 m²
Garden area
414 m²
Climate zone
NatHERS climate zone 18
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Solar panels
1 kW
Rainwater tank
20,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 120 m², single glazing 5 m², double glazing 115 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (cold zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 5 star (cold zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (cold zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 5 star (cold zone)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (rockwool batts, roll or pump-in)
  • Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
  • Garage floor: concrete slab on ground (not specified)
  • External wall: cavity brick; frame: no frame (polystyrene)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)

Certificate 1777577S_02, issued 23 January 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
AccuRate Sustainability V2.4.3.21 SP1
Rated on
23 Jan 2025
Wall insulation
R5.0, R1.0, R2.5
Ceiling insulation
R3.0
Floor insulation
R3.0
Living room glazing by direction
N 4.1 m², E 8.4 m², S 2.3 m²
All glazing by direction
N 31.2 m², E 50.5 m², S 18.3 m², W 21.9 m²

Roof

  • Metal deck uninsulated, medium colour
  • Metal deck plasterboard ceiling R4.6, medium colour
  • Concrete roof terrace R3.0, medium colour
  • Metal deck/cedar clad ceiling R4.6, medium colour

Window types

  • BRZ-003-13 A 52mm Altair Louvre Window System SG 6LE: U-value 4.3, SHGC 0.57
  • DOW-022-07 B TB Aluminium Sliding Window DG LightBridge_ClrS0_4-12-4: U-value 2.1, SHGC 0.51
  • DOW-023-09 B TB Al Fixed-DG with TPS Spacer LightBridge_ClrSI_6.38-10-4: U-value 1.7, SHGC 0.47
  • DOW-025-08 B TB Aluminium Sliding Door DG LightBridge_ClrS0_4-12-4: U-value 1.9, SHGC 0.49
  • DOW-021-08 B Thermally Broken Aluminium Awning Window DG LightBridge_ClrS0_4-12-4: U-value 1.9, SHGC 0.44
  • ALS-002-12 A 76mm ViewMax DoubleHung Window DG LightBridge_ClrS0_4-8-4: U-value 3.5, SHGC 0.45
  • AWS-053-06 B COM THERMALHEART 804-852 HINGED DOOR DG 638CPClr/12Ar/6Clr: U-value 2.8, SHGC 0.37

Window schedule

  • Bed 1, window DOW-022-07 B: 350 × 2,700 mm facing S
  • Bed 1, window DOW-025-08 B: 2,100 × 1,100 mm facing N
  • Bed 1, window ALS-002-12 A: 2,100 × 1,100 mm facing N
  • Bed 1, window DOW-023-09 B: 500 × 2,200 mm facing N
  • Bed 2, window DOW-025-08 B: 2,100 × 1,100 mm facing N
  • Bed 2, window ALS-002-12 A: 2,100 × 1,100 mm facing N
  • Bed 2, window DOW-023-09 B: 500 × 2,200 mm facing N
  • Entry/hall, window DOW-022-07 B: 350 × 2,600 mm facing S
  • Entry/hall, window AWS-053-06 B: 2,100 × 820 mm facing S
  • A W10 louvre HL: 500 × 820 mm facing S
  • Entry/hall, window DOW-023-09 B: 2,600 × 3,100 mm facing W
  • Entry/hall, window DOW-023-09 B: 950 × 800 mm facing W
  • Entry/hall, window DOW-023-09 B: 450 × 800 mm facing W
  • Entry/hall, window BRZ-003-13 A: 1,200 × 800 mm facing W
  • Entry/hall, window DOW-023-09 B: 2,100 × 2,300 mm facing N
  • Entry/hall, window AWS-053-06 B: 2,100 × 1,000 mm facing N
  • Entry/hall, window DOW-023-09 B: 500 × 3,300 mm facing N
  • Bath GF, window DOW-023-09 B: 2,100 × 550 mm facing S
  • Bath GF, window BRZ-003-13 A: 500 × 550 mm facing S
  • Bed 3, window ALS-002-12 A: 2,100 × 600 mm facing E
  • Bed 3, window DOW-025-08 B: 2,100 × 3,700 mm facing E
  • Bed 3, window DOW-023-09 B: 500 × 4,300 mm facing E
  • Laundry, window AWS-053-06 B: 2,100 × 820 mm facing E
  • Laundry, window DOW-023-09 B: 500 × 820 mm facing E
  • Rumpus, window DOW-023-09 B: 900 × 900 mm facing S
  • Rumpus, window ALS-002-12 A: 1,200 × 900 mm facing S
  • Rumpus, window DOW-023-09 B: 500 × 900 mm facing S
  • Rumpus, window DOW-025-08 B: 2,100 × 2,400 mm facing E
  • Rumpus, window DOW-022-07 B: 1,100 × 1,300 mm facing E
  • Rumpus, window DOW-023-09 B: 500 × 3,800 mm facing E
  • B W5 fixed lower: 1,000 × 1,300 mm facing E
  • Rumpus, window DOW-023-09 B: 2,055 × 1,310 mm facing N
  • Rumpus, window DOW-021-08 B: 1,110 × 1,310 mm facing N
  • FF, window DOW-023-09 B: 350 × 750 mm facing W
  • FF, window DOW-023-09 B: 350 × 750 mm facing W
  • FF, window DOW-021-08 B: 350 × 750 mm facing W
  • FF, window DOW-022-07 B: 1,300 × 2,600 mm facing W
  • FF, window DOW-023-09 B: 350 × 2,600 mm facing W
  • FF, window DOW-023-09 B: 350 × 750 mm facing W
  • FF, window DOW-022-07 B: 550 × 2,650 mm facing N
  • FF, window DOW-023-09 B: 350 × 2,650 mm facing N
  • FF, window DOW-023-09 B: 350 × 700 mm facing N
  • FF, window DOW-022-07 B: 550 × 1,600 mm facing N
  • FF, window DOW-023-09 B: 350 × 1,350 mm facing N
  • FF, window DOW-023-09 B: 350 × 1,350 mm facing N
  • FF, window DOW-023-09 B: 350 × 2,900 mm facing N
  • FF, window DOW-023-09 B: 700 × 1,200 mm facing N
  • FF, window DOW-021-08 B: 600 × 1,200 mm facing N
  • FF, window DOW-023-09 B: 2,400 × 800 mm facing E
  • FF, window DOW-025-08 B: 2,400 × 2,600 mm facing E
  • FF, window DOW-022-07 B: 1,400 × 1,200 mm facing E
  • FF, window DOW-023-09 B: 1,000 × 1,200 mm facing E
  • FF, window DOW-023-09 B: 2,400 × 2,000 mm facing S
  • FF, window DOW-023-09 B: 1,400 × 1,200 mm facing S
  • ALS-002-12 A W23 DH: 1,400 × 900 mm facing E
  • ALS-002-12 A W23 DH: 1,400 × 900 mm facing E
  • B W23 F upper: 1,400 × 900 mm facing E
  • FF, window DOW-023-09 B: 1,000 × 2,700 mm facing E
  • Master Bed, window BRZ-003-13 A: 1,400 × 650 mm facing E
  • Master Bed, window DOW-023-09 B: 1,000 × 650 mm facing E
  • Master Bed, window BRZ-003-13 A: 1,400 × 650 mm facing E
  • Master Bed, window DOW-023-09 B: 1,400 × 1,700 mm facing E
  • Master Bed, window DOW-023-09 B: 2,800 × 1,400 mm facing E
  • Master Bed, window DOW-023-09 B: 400 × 3,000 mm facing E
  • Master Bed, window DOW-023-09 B: 2,800 × 700 mm facing S
  • Bath FF, window BRZ-003-13 A: 1,800 × 600 mm facing S
  • Bath FF, window DOW-023-09 B: 350 × 1,700 mm facing S
  • Bath FF, window DOW-023-09 B: 350 × 1,100 mm facing S
  • Bath FF, window DOW-023-09 B: 350 × 1,450 mm facing W
  • landing/reading, window DOW-025-08 B: 2,400 × 1,200 mm facing W
  • landing/reading, window DOW-023-09 B: 2,400 × 900 mm facing W
  • landing/reading, window ALS-002-12 A: 1,400 × 600 mm facing W

Certificate 0011617891-01, issued 23 January 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.