North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
12 Dacres Street Vincentia NSW 2540
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 3,000 litre rainwater tank.
Key features
- Windows
- Up to aluminium frames 135.5 m², double glazing 135.5 m²
- Wall insulation
- All external walls none
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 7 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 69 (target 69)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -38
- Heating load
- 31 MJ/m² a year
- Cooling load
- 27 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 238.5 m²
- Unconditioned floor area
- 19.9 m²
- Site area
- 828 m²
- Roof area
- 335 m²
- Garden area
- 459 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Gas instantaneous with a performance of 7 stars
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 6 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 135.5 m², double glazing 135.5 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls none
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1745704S, issued 1 May 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.