10 White Gum Road Ulladulla NSW 2539
BASIX certificate and NatHERS rating
Finding the block on the map…
This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 5 kW of solar panels and a 6,000 litre rainwater tank.
Key features
- Windows
- 22 windows and glazed doors: Aluminium B SG Low Solar Gain Low-E; Trend ThermaRes Thermally Broken Fixed Window; Trend ThermaRes Thermally Broken Sliding Window and 2 more types
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
- Hot water
- Electric instantaneous
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom); Wood heater (living area)
BASIX certificate
- Energy score
- 69 (target 69)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -28
- Heating load
- 37 MJ/m² a year
- Cooling load
- 23 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 213.2 m²
- Unconditioned floor area
- 19.9 m²
- Site area
- 14,550 m²
- Roof area
- 500 m²
- Garden area
- 380 m²
- Climate zone
- NatHERS climate zone 18
- Hot water
- Electric instantaneous
- Solar panels
- 5 kW
- Rainwater tank
- 6,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 89 m², double glazing 89 m²
Heating
- Living area: wood heater; Energy rating: n/a
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (cold zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 5 star (cold zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 5 star (cold zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1770220S_02, issued 14 November 2024, from the council's DA documents.
NatHERS certificate
- Star rating
- 7.1 stars
- Rated with
- Hero 4.1
- Rated on
- 24 Oct 2024
- Living room glazing by direction
- E 15.2 m², S 9.1 m², W 13.5 m²
- All glazing by direction
- N 21.6 m², E 21.8 m², S 32.5 m², W 18.4 m²
Roof
- Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.30, medium colour
Window types
- ALM-002-04 A Aluminium B SG Low Solar Gain Low-E: U-value 5.6, SHGC 0.41
- TND-100-025 Trend ThermaRes Thermally Broken Fixed Window: U-value 1.9, SHGC 0.5
- TND-104-022 Trend ThermaRes Thermally Broken Sliding Window: U-value 2.26, SHGC 0.5
- TND-108-034 Trend ThermaRes Thermally Broken Sliding Door: U-value 2.11, SHGC 0.47
- TND-111-036 Trend ThermaArc Thermally Broken Hinged Door: U-value 2.33, SHGC 0.23
- TND-111-037 Trend ThermaArc Thermally Broken Hinged Door: U-value 2.33, SHGC 0.39
Window schedule
- BATH, window TND-104-022: 1,800 × 2,400 mm facing N
- BED 1, window TND-111-036: 2,400 × 1,000 mm facing S
- BED 1, window TND-111-036: 2,400 × 1,000 mm facing S
- BED 1, window ALM-002-04 A: 2,400 × 1,000 mm facing S
- BED 1, window ALM-002-04 A: 2,400 × 1,000 mm facing S
- BED 1, window TND-104-022: 900 × 2,700 mm facing W
- BED 1, window TND-104-022: 900 × 2,700 mm facing E
- BED 2, window TND-104-022: 1,800 × 2,400 mm facing N
- BED 2, window TND-104-022: 900 × 2,700 mm facing W
- BED 3, window TND-104-022: 1,800 × 2,400 mm facing N
- BED 4, window TND-104-022: 1,800 × 2,400 mm facing N
- ENS, window TND-104-022: 1,200 × 1,800 mm facing E
- ENTRY/HALWAY, window TND-111-037: 2,400 × 1,800 mm facing N
- ENTRY/HALWAY, window TND-108-034: 2,400 × 3,800 mm facing S
- ENTRY/HALWAY, window TND-100-025: 2,400 × 1,950 mm facing S
- KITCHEN/LIVING, window TND-100-025: 1,900 × 2,400 mm facing S
- KITCHEN/LIVING, window TND-100-025: 1,900 × 2,400 mm facing S
- KITCHEN/LIVING, window TND-108-034: 2,400 × 3,100 mm facing W
- KITCHEN/LIVING, window TND-104-022: 1,900 × 3,200 mm facing W
- KITCHEN/LIVING, window TND-108-034: 2,400 × 3,800 mm facing E
- KITCHEN/LIVING, window TND-104-022: 1,900 × 3,200 mm facing E
- LNDRY / MUD, window TND-111-037: 2,400 × 820 mm facing E
Certificate HR-JHKOJA-01, issued 24 October 2024, from the council's DA documents. Verify this certificate