66 Knowles Avenue Matraville NSW 2036

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 3.2 kW of solar panels and a 5,000 litre rainwater tank.

Key features

Windows
Up to aluminium frames 71 m², single glazing 61 m², double glazing 10 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Materials score
-50
Heating load
19 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
5
Conditioned floor area
254 m²
Unconditioned floor area
15 m²
Site area
493 m²
Roof area
208 m²
Garden area
204 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
3.2 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 71 m², single glazing 61 m², double glazing 10 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 Star (old label)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 Star (old label)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 Star (old label)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 Star (old label)

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (not specified)
  • Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: no frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - untreated softwood (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1854191S_02, issued 9 July 2026, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.