Skip to main content

51 Bay Parade Malabar NSW 2036

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 2 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 75 against 72 for energy and 46 against 40 for water.

Key features

Windows
Up to aluminium frames 108.9 m², double glazing 108.9 m²
Wall insulation
Rockwool batts, roll or pump-in+ foil/sarking
Roof and ceiling insulation
Ceiling: rockwool batts, roll or pump-in; roof: none; Ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket
Hot water
Electric boosted solar
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
75 (target 72)
Water score
46 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
14 MJ/m² a year
Cooling load
11 MJ/m² a year
Bedrooms
4
Conditioned floor area
241.5 m²
Unconditioned floor area
15.7 m²
Site area
320 m²
Roof area
191 m²
Garden area
105 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric boosted solar
Solar panels
2 kW
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 108.9 m², double glazing 108.9 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (rockwool batts, roll or pump-in)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: light steel frame (fibreglass batts or roll)
  • Floor: suspended floor above garage, concrete - suspended; frame: light steel frame (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (rockwool batts, roll or pump-in)
  • External wall: concrete block/plasterboard; frame: timber - untreated softwood (rockwool batts, roll or pump-in+ foil/sarking)
  • External wall: cavity brick; frame: no frame (rockwool batts, roll or pump-in+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
  • Ceiling and roof: flat ceiling / pitched roof, concrete - plasterboard internal, timber - untreated softwood (ceiling: rockwool batts, roll or pump-in; roof: none.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil backed blanket.)

Certificate 1742081S, issued 2 April 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related