North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
277 Storey Street Maroubra NSW 2035
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 3 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy target, scoring 74 against 72.
Key features
- Windows
- Up to aluminium frames 232 m², double glazing 232 m²
- Wall insulation
- Foil-foam composite board; No added insulation; Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
Built by Residential Certifying.
BASIX certificate
- Energy score
- 74 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 21 MJ/m² a year
- Cooling load
- 10 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 400.4 m²
- Unconditioned floor area
- 26.6 m²
- Site area
- 980 m²
- Roof area
- 290 m²
- Garden area
- 315 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Solar panels
- 3 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 232 m², double glazing 232 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: no frame (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: no frame (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: cavity brick; frame: no frame (foil-foam composite board)
- External wall: concrete block/plasterboard; frame: no frame (no added insulation)
- External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1744383S_02, issued 23 April 2024, from the council's DA documents.