Skip to main content

23 Shackel Avenue Clovelly NSW 2031

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7.1 stars out of 10. Its BASIX certificate commits it to 1.5 kW of solar panels and a 1,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 85 against 72 for energy and 44 against 40 for water.

Key features

Windows
23 windows and glazed doors: Timber B DG Air Fill Clear-Clear; Timber A DG Air Fill Clear-Clear
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R4, roof Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
Hot water
Electric boosted solar with a performance of 15 to 20 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
85 (target 72)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
1
Heating load
20 MJ/m² a year
Cooling load
10 MJ/m² a year
Bedrooms
5
Conditioned floor area
206 m²
Unconditioned floor area
32 m²
Site area
331 m²
Roof area
179 m²
Garden area
85 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric boosted solar with a performance of 15 to 20 STCs or better
Solar panels
1.5 kW
Rainwater tank
1,000 litres
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 6 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
timber frames 72 m², double glazing 72 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, 50% cement substitute, conventional slab (polyurethane)
  • Garage floor: concrete - suspended; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (polyurethane)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1765540S_02, issued 24 November 2024, from the council's DA documents.

NatHERS certificate

Star rating
7.1 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
16 Sep 2024
Wall insulation
R2.5
Ceiling insulation
R4
Floor insulation
R2.5, R1.7, R4.0
Living room glazing by direction
N 9.3 m², S 10.2 m², SW 1.3 m², W 10.4 m²
All glazing by direction
N 17.3 m², S 21.3 m², SW 1.3 m², W 27.7 m²

Roof

  • Waterproofing Membrane No Insulation, Only an Air Gap, medium colour
  • Corrugated Iron Timber Frame No Insulation, Only an Air Gap, medium colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, No Air Gap Above R1.5, dark colour

Window types

  • TIM-004-01 W Timber B DG Air Fill Clear-Clear: U-value 3, SHGC 0.56
  • TIM-003-01 W Timber A DG Air Fill Clear-Clear: U-value 3, SHGC 0.48

Window schedule

  • Bed 5, window TIM-004-01 W: 1,115 × 1,115 mm facing S
  • Bed 5, window TIM-004-01 W: 2,296 × 1,560 mm facing S
  • study, window TIM-003-01 W: 920 × 614 mm facing W
  • bath basement, window TIM-003-01 W: 920 × 307 mm facing W
  • ground entry, window TIM-004-01 W: 2,564 × 108 mm facing W
  • ground entry, window TIM-004-01 W: 2,564 × 196 mm facing W
  • ground entry, window TIM-004-01 W: 2,572 × 900 mm facing N
  • Bedroom 1, window TIM-004-01 W: 2,572 × 801 mm facing S
  • Bedroom 1, window TIM-004-01 W: 2,100 × 2,000 mm facing S
  • Ensuite, window TIM-004-01 W: 2,572 × 583 mm facing W
  • Ensuite, window TIM-003-01 W: 2,572 × 350 mm facing W
  • Ensuite, window TIM-004-01 W: 2,572 × 2,232 mm facing W
  • bath ground, window TIM-003-01 W: 2,572 × 500 mm facing W
  • Bedroom 4, window TIM-003-01 W: 2,564 × 815 mm facing W
  • Bedroom 3, window TIM-003-01 W: 2,564 × 815 mm facing W
  • Bedroom 2, window TIM-004-01 W: 2,572 × 1,660 mm facing N
  • Bedroom 2, window TIM-004-01 W: 2,564 × 575 mm facing N
  • Bedroom 2, window TIM-003-01 W: 2,564 × 815 mm facing W
  • liv din kit sit, window TIM-004-01 W: 2,525 × 4,032 mm facing S
  • liv din kit sit, window TIM-004-01 W: 2,658 × 490 mm facing SW
  • liv din kit sit, window TIM-004-01 W: 1,813 × 773 mm facing W
  • liv din kit sit, window TIM-004-01 W: 1,813 × 4,950 mm facing W
  • liv din kit sit, window TIM-004-01 W: 2,168 × 4,286 mm facing N

Certificate 0009755497, issued 16 September 2024, from the council's DA documents. Verify this certificate

Other certificates for this address

BASIX certificate, certificate 1765540S, issued 22 September 2024

BASIX certificate

Energy score
75 (target 72)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
1
Heating load
20 MJ/m² a year
Cooling load
10 MJ/m² a year
Bedrooms
5
Conditioned floor area
206 m²
Unconditioned floor area
32 m²
Site area
331 m²
Roof area
179 m²
Garden area
85 m²
Climate zone
NatHERS climate zone 56
Hot water
Electric boosted solar with a performance of 15 to 20 STCs or better
Solar panels
1.5 kW
Rainwater tank
1,000 litres
Fixtures
Showerheads 4 star, toilets 5 star, kitchen taps 6 star, basin taps 5 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
timber frames 72 m², double glazing 72 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Construction and insulation

  • Floor: concrete slab on ground, 50% cement substitute, conventional slab (polyurethane)
  • Garage floor: concrete - suspended; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (no added insulation)
  • External wall: cavity brick; frame: no frame (polyurethane)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
  • Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)