BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 4 kW of solar panels. It beat its BASIX energy target, scoring 96 against 72.
Key features
- Windows
- Up to aluminium frames 39.1 m², timber frames 17 m², composite frames 6.6 m², single glazing 56.1 m², double glazing 6.6 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 96 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- 9
- Heating load
- 16 MJ/m² a year
- Cooling load
- 14 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 164.9 m²
- Unconditioned floor area
- 19.3 m²
- Site area
- 276 m²
- Roof area
- 116 m²
- Garden area
- 72 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump
- Solar panels
- 4 kW
- Fixtures
- Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 39.1 m², timber frames 17 m², composite frames 6.6 m², single glazing 56.1 m², double glazing 6.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (foil-foam composite board)
- Floor: suspended floor above enclosed subfloor, hard wood; frame: timber - hardwood predominant incl. glue laminated beams (foil/sarking)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
- External wall: reverse brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - terracotta tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1792887S, issued 24 April 2025, from the council's DA documents.