10 Keith Street Clovelly NSW 2031
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 4.6 stars out of 10.
Key features
- Windows
- 25 windows and glazed doors: Aluminium B SG High Solar Gain Low-E; Al Thermally Broken A DG Argon Fill High Solar Gain low-E - Clear; Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear
- Wall insulation
- No added insulation; Or R1.70 including construction
- Roof and ceiling insulation
- Roof Added insulation absorptance Roof Colour FLAT-01: Flat Framed / Skillion Metal Roof + Flat Ceiling 1.30, light colour
Built by Beyond Build Constructions.
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Construction and insulation
- Suspended floor with open subfloor: framed (R0.7). R0.8 (down) (or R1.50 including construction) N/A
- Suspended floor with enclosed subfloor: framed (R0.7). R0.60 (down) (or R1.30 including construction) N/A
- External wall: cavity brick (no added insulation)
- External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
- Internal wall shared with garage: plasterboard (R0.36)
- Flat ceiling, pitched roof ceiling: R2.25 (up), roof: foil/sarking light (solar absorptance < 0.475)
- Raked ceiling, pitched/skillion roof: framed ceiling: R2.26 (up), roof: foil/sarking light (solar absorptance < 0.475)
Certificate A1748127_03, issued 11 October 2024, from the council's DA documents.
NatHERS certificate
- Star rating
- 4.6 stars
- Rated with
- HERO v1.2-beta
- Rated on
- 06 Oct 2021
- Living room glazing by direction
- NNE 8 m², ESE 3.3 m², SSW 2.8 m², WNW 15.5 m²
- All glazing by direction
- NNE 28.9 m², ESE 18.8 m², SSW 18.5 m², WNW 33.3 m²
Roof
- Added insulation absorptance Roof Colour FLAT-01: Flat Framed / Skillion Metal Roof + Flat Ceiling 1.30, light colour
Window types
- ALM-002-03 A Aluminium B SG High Solar Gain Low-E: U-value 5.4, SHGC 0.58
- ATB-005-03 B Al Thermally Broken A DG Argon Fill High Solar Gain low-E - Clear: U-value 2.91, SHGC 0.44
- ATB-006-03 B Al Thermally Broken B DG Argon Fill High Solar Gain low-E - Clear: U-value 2.9, SHGC 0.51
Window schedule
- Bathroom, window ALM-002-03 A: 750 × 1,500 mm facing NNE
- Batroom _first, window ATB-005-03 B: 2,700 × 1,825 mm facing ESE
- Bedroom_03, window ATB-005-03 B: 2,700 × 1,420 mm facing WNW
- (SC 0.30) Bedroom_03, window ALM-002-03 A: 2,700 × 900 mm facing NNE
- Bedroom_04, window ATB-005-03 B: 2,700 × 1,420 mm facing WNW
- (SC 0.30) Bedroom_04, window ALM-002-03 A: 2,700 × 900 mm facing SSW
- Ground_hall, window ATB-006-03 B: 1,350 × 3,750 mm facing NNE
- Guest_bed, window ATB-005-03 B: 3,000 × 1,120 mm facing ESE
- Guest_bed, window ALM-002-03 A: 750 × 2,600 mm facing NNE
- Hall, window ATB-005-03 B: 1,190 × 3,680 mm facing NNE
- (SC 0.30) Hall, window ATB-005-03 B: 2,500 × 2,380 mm facing SSW
- Kitchen/Living/pantry, window ALM-002-03 A: 750 × 3,160 mm facing NNE
- Kitchen/Living/pantry, window ALM-002-03 A: 750 × 3,160 mm facing NNE
- Kitchen/Living/pantry, window ATB-005-03 B: 2,700 × 1,220 mm facing ESE
- Kitchen/Living/pantry, window ATB-006-03 B: 700 × 4,000 mm facing SSW
- Kitchen/Living/pantry, window ATB-006-03 B: 2,700 × 5,735 mm facing WNW
- Laundry, window ATB-005-03 B: 2,700 × 900 mm facing SSW
- Lounge, window ATB-005-03 B: 1,190 × 2,695 mm facing NNE
- Master_Bedroom/WIR, window ATB-005-03 B: 1,190 × 5,000 mm facing NNE
- Master_Bedroom/WIR, window ATB-005-03 B: 2,190 × 1,520 mm facing WNW
- (SC 0.60) Master_Bedroom/WIR, window ATB-006-03 B: 2,700 × 2,670 mm facing ESE
- Study, window ATB-006-03 B: 2,700 × 1,220 mm facing WNW
- Study_first, window ALM-002-03 A: 2,700 × 900 mm facing SSW
- Study_first, window ATB-005-03 B: 1,990 × 1,800 mm facing WNW
- (SC 0.60) ensuite, window ALM-002-03 A: 2,700 × 900 mm facing SSW
Certificate HR-Z8JHAW-01, issued 6 October 2021, from the council's DA documents. Verify this certificate
Other certificates for this address
BASIX certificate (alterations and additions), certificate A1748127_02, issued 29 July 2024
BASIX certificate (alterations and additions)
This BASIX certificate is for alterations and additions, such as an extension or a pool, rather than a whole new house.
- LED lighting
- Yes
Construction and insulation
- Suspended floor with open subfloor: framed (R0.7). R0.8 (down) (or R1.50 including construction) N/A
- Suspended floor with enclosed subfloor: framed (R0.7). R0.60 (down) (or R1.30 including construction) N/A
- External wall: cavity brick (no added insulation)
- External wall: framed (weatherboard, fibro, metal clad) R1.30 (or R1.70 including construction)
- Internal wall shared with garage: plasterboard (R0.36)
- Flat ceiling, pitched roof ceiling: R2.25 (up), roof: foil/sarking light (solar absorptance < 0.475)
- Raked ceiling, pitched/skillion roof: framed ceiling: R2.26 (up), roof: foil/sarking light (solar absorptance < 0.475)
Certificate A1748127_02, issued 29 July 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.