Skip to main content

John Oxley Drive Thrumster NSW 2444

Finding the block on the map…

BASIX certificate and NatHERS rating

This home beat its BASIX energy and water targets, scoring 73 against 70 for energy and 64 against 40 for water.

Key features

Windows
Up to aluminium frames 31.6 m², single glazing 18.8 m², double glazing 12.8 m²
Wall insulation
No added insulation; Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

BASIX certificate

Energy score
73 (target 70)
Water score
64 (target 40)
Thermal performance
Pass
Materials score
-86
Heating load
39 MJ/m² a year
Cooling load
12 MJ/m² a year
Bedrooms
4
Conditioned floor area
125.6 m²
Unconditioned floor area
12.3 m²
Site area
458 m²
Roof area
247 m²
Garden area
183 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 31.6 m², single glazing 18.8 m², double glazing 12.8 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1833183S, issued 15 February 2026, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1833182S, issued 15 February 2026

BASIX certificate

Energy score
73 (target 70)
Water score
52 (target 40)
Thermal performance
Pass
Materials score
-47
Heating load
35 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
4
Conditioned floor area
130.3 m²
Unconditioned floor area
11 m²
Site area
458 m²
Roof area
254 m²
Garden area
216 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 32.9 m², single glazing 22.2 m², double glazing 10.7 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1833182S, issued 15 February 2026, from the council's DA documents.

BASIX certificate, certificate 1833181S, issued 15 February 2026

BASIX certificate

Energy score
73 (target 70)
Water score
62 (target 40)
Thermal performance
Pass
Materials score
-87
Heating load
36 MJ/m² a year
Cooling load
14 MJ/m² a year
Bedrooms
4
Conditioned floor area
125.6 m²
Unconditioned floor area
12.3 m²
Site area
525 m²
Roof area
247 m²
Garden area
250 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 32.1 m², single glazing 22 m², double glazing 10.1 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1833181S, issued 15 February 2026, from the council's DA documents.

BASIX certificate, certificate 1833180S, issued 15 February 2026

BASIX certificate

Energy score
73 (target 70)
Water score
51 (target 40)
Thermal performance
Pass
Materials score
-55
Heating load
35 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
4
Conditioned floor area
130.3 m²
Unconditioned floor area
11 m²
Site area
531 m²
Roof area
255 m²
Garden area
260 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 26 to 30 STCs or better
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 32 m², single glazing 21.3 m², double glazing 10.7 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: please select (not specified)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1833180S, issued 15 February 2026, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related