Skip to main content

99 Phar Lap Circuit Port Macquarie NSW 2444

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to a 2,000 litre rainwater tank. It beat its BASIX water target, scoring 43 against 40.

Key features

Windows
Up to aluminium frames 45.7 m², single glazing 45.7 m²
Wall insulation
Polystyrene; Fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
70 (target 70)
Water score
43 (target 40)
Thermal performance
Pass
Materials score
-65
Heating load
32 MJ/m² a year
Cooling load
18 MJ/m² a year
Bedrooms
3
Conditioned floor area
177.6 m²
Unconditioned floor area
13.7 m²
Site area
357 m²
Roof area
167 m²
Garden area
140 m²
Climate zone
NatHERS climate zone 15
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 45.7 m², single glazing 45.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (polystyrene)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: cavity brick; frame: no frame (polystyrene)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: cavity brick; frame: no frame (polystyrene)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1784842S, issued 25 February 2025, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1784840S, issued 25 February 2025

BASIX certificate

Energy score
70 (target 70)
Water score
44 (target 40)
Thermal performance
Pass
Materials score
-22
Heating load
35 MJ/m² a year
Cooling load
15 MJ/m² a year
Bedrooms
3
Conditioned floor area
147.1 m²
Unconditioned floor area
11.3 m²
Site area
382 m²
Roof area
211 m²
Garden area
155 m²
Climate zone
NatHERS climate zone 15
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 22.7 m², single glazing 22.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (polystyrene)
  • Garage floor: concrete - suspended; frame: no frame (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1784840S, issued 25 February 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.