North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
75 Riverside Drive Riverside NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels and an 80,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 94 against 70 for energy and 94 against 40 for water.
Key features
- Windows
- Up to aluminium frames 54.2 m², single glazing 50.9 m², double glazing 3.3 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: none; roof: foil backed blanket; Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 94 (target 70)
- Water score
- 94 (target 40)
- Materials score
- -100
- Heating load
- 29 MJ/m² a year
- Cooling load
- 18 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 237.8 m²
- Unconditioned floor area
- 15.6 m²
- Site area
- 1,056 m²
- Roof area
- 417 m²
- Garden area
- 450 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 31 to 35 STCs or better
- Solar panels
- 6.6 kW
- Rainwater tank
- 80,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 54.2 m², single glazing 50.9 m², double glazing 3.3 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Garage floor: concrete - suspended; frame: no frame (not specified)
- External wall: AAC veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- Internal wall shared with garage: 75 mm AAC panel; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (not specified)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: none; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1848231S, issued 27 May 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.