North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
6 Imperial Place Thrumster NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home beat its BASIX energy and water targets, scoring 72 against 70 for energy and 59 against 40 for water.
Key features
- Windows
- Up to aluminium frames 53.5 m², single glazing 5.3 m², double glazing 48.2 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric boosted solar with a performance of 21 to 25 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Better Homes.
BASIX certificate
- Energy score
- 72 (target 70)
- Water score
- 59 (target 40)
- Thermal performance
- Pass
- Materials score
- -42
- Heating load
- 26 MJ/m² a year
- Cooling load
- 25 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 188.8 m²
- Unconditioned floor area
- 15.5 m²
- Site area
- 547 m²
- Roof area
- 251 m²
- Garden area
- 240 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric boosted solar with a performance of 21 to 25 STCs or better
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 53.5 m², single glazing 5.3 m², double glazing 48.2 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 2.5 - 3.0
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1833809S, issued 19 February 2026, from the council's DA documents.
Is this your home? Ask us to remove these details.