North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
6 Graham Street Bonny Hills NSW 2445
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 4,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 42 against 40 for water.
Key features
- Windows
- Up to aluminium frames 50 m², single glazing 12.8 m², double glazing 37.2 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Mozeley & Dodds Constructions.
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 42 (target 40)
- Thermal performance
- Pass
- Materials score
- 0
- Heating load
- 25 MJ/m² a year
- Cooling load
- 25 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 167.8 m²
- Unconditioned floor area
- 10.2 m²
- Site area
- 603 m²
- Roof area
- 195 m²
- Garden area
- 376 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 26 to 30 STCs or better
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Induction
- Maximum glazing
- aluminium frames 50 m², single glazing 12.8 m², double glazing 37.2 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1821226S, issued 11 November 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.