North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
520 Farrawells Road Telegraph Point NSW 2441
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to a 20,000 litre rainwater tank. It beat its BASIX water target, scoring 79 against 40.
Key features
- Windows
- Up to aluminium frames 49.6 m², single glazing 49.6 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; No added insulation
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric boosted solar
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 69 (target 69)
- Water score
- 79 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 27 MJ/m² a year
- Cooling load
- 9 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 252.7 m²
- Unconditioned floor area
- 23.5 m²
- Site area
- 97,600 m²
- Roof area
- 588 m²
- Garden area
- 800 m²
- Climate zone
- NatHERS climate zone 11
- Hot water
- Electric boosted solar
- Rainwater tank
- 20,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 49.6 m², single glazing 49.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 Star (old label
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 Star (old label
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 Star (old label)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: cavity brick; frame: no frame (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1750271S, issued 4 June 2024, from the council's DA documents.