BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 2 kW of solar panels. It beat its BASIX energy and water targets, scoring 89 against 70 for energy and 47 against 40 for water.

Key features

Windows
Up to aluminium frames 29.8 m², single glazing 24.8 m², double glazing 5 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Hibbard Homes.

BASIX certificate

Energy score
89 (target 70)
Water score
47 (target 40)
Thermal performance
Pass
Materials score
-45
Heating load
34 MJ/m² a year
Cooling load
17 MJ/m² a year
Bedrooms
4
Conditioned floor area
143.1 m²
Unconditioned floor area
13.1 m²
Site area
509 m²
Roof area
263 m²
Garden area
232 m²
Climate zone
NatHERS climate zone 15
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
2 kW
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 29.8 m², single glazing 24.8 m², double glazing 5 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1803348S_02, issued 9 July 2025, from the council's DA documents.