North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
41 Acton Street Thrumster NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels. It beat its BASIX energy target, scoring 98 against 70.
Key features
- Windows
- Up to aluminium frames 50 m², single glazing 16.6 m², double glazing 33.4 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking; Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Better Homes.
BASIX certificate
- Energy score
- 98 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -58
- Heating load
- 33 MJ/m² a year
- Cooling load
- 17 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 193.5 m²
- Unconditioned floor area
- 53.5 m²
- Site area
- 671 m²
- Roof area
- 261 m²
- Garden area
- 300 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric boosted solar with a performance of 31 to 35 STCs or better
- Solar panels
- 6.6 kW
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 50 m², single glazing 16.6 m², double glazing 33.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: laminated veneer lumber (LVL) (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: cavity brick; frame: no frame (no added insulation)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1818221S, issued 22 October 2025, from the council's DA documents.