North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
40 Hastings River Drive, Port Macquarie
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 3.3 kW of solar panels and a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 91 against 70 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 56.5 m², single glazing 8.1 m², double glazing 48.4 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Yarrum House And Land.
BASIX certificate
- Energy score
- 91 (target 70)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -50
- Heating load
- 35 MJ/m² a year
- Cooling load
- 15 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 245 m²
- Unconditioned floor area
- 17.9 m²
- Site area
- 566 m²
- Roof area
- 320 m²
- Garden area
- 30 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 3.3 kW
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 56.5 m², single glazing 8.1 m², double glazing 48.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 Star (old label)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3.5 Star (old label)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3.5 Star (old label)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above open subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: external insulated façade system (EIFS); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: concrete block/plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (metal clad); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: concrete block/plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1801210S, issued 24 June 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.