North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
28 Dent Crescent Port Macquarie NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 5 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 46 against 40 for water.
Key features
- Windows
- Up to aluminium frames 80.3 m², double glazing 80.3 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric boosted solar with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
Built by Sorensen & Caldon.
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 46 (target 40)
- Thermal performance
- Pass
- Materials score
- -12
- Heating load
- 25 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 242.3 m²
- Unconditioned floor area
- 1.6 m²
- Site area
- 597 m²
- Roof area
- 213 m²
- Garden area
- 164 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric boosted solar with a performance of 26 to 30 STCs or better
- Solar panels
- 5 kW
- Rainwater tank
- 5,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 80.3 m², double glazing 80.3 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (not specified)
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall shared with garage: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1775057S, issued 28 November 2024, from the council's DA documents.