North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
20 Riberry Road Thrumster NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 2 kW of solar panels. It beat its BASIX energy and water targets, scoring 88 against 70 for energy and 47 against 40 for water.
Key features
- Windows
- Up to aluminium frames 28.2 m², single glazing 28.2 m²
- Wall insulation
- All external walls fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Hibbard Homes.
BASIX certificate
- Energy score
- 88 (target 70)
- Water score
- 47 (target 40)
- Thermal performance
- Pass
- Materials score
- -48
- Heating load
- 34 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 143.2 m²
- Unconditioned floor area
- 13.1 m²
- Site area
- 465 m²
- Roof area
- 263 m²
- Garden area
- 198 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 2 kW
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 28.2 m², single glazing 28.2 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, 30% cement substitute, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1765195S, issued 19 September 2024, from the council's DA documents.