North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
2 Parkwood Court Port Macquarie NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 6.6 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 100 against 70 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 44.2 m², single glazing 44.2 m²
- Wall insulation
- Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: rockwool batts, roll or pump-in; roof: foil/sarking
- Hot water
- Electric storage
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Pycon Homes & Constructions.
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -29
- Heating load
- 29 MJ/m² a year
- Cooling load
- 22 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 195.6 m²
- Unconditioned floor area
- 17.1 m²
- Site area
- 797 m²
- Roof area
- 284 m²
- Garden area
- 170 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric storage
- Solar panels
- 6.6 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 44.2 m², single glazing 44.2 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (fibreglass batts or roll)
- Floor: suspended floor above enclosed subfloor, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, treated softwood; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (fibreglass batts or roll)
- External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil/sarking.)
Certificate 1747393S_03, issued 26 July 2024, from the council's DA documents.
Is this your home? Ask us to remove these details.