Skip to main content

13 Galena Grove Lake Cathie NSW 2445

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 3.3 kW of solar panels. It beat its BASIX energy target, scoring 89 against 70.

Key features

Windows
Up to aluminium frames 64.2 m², single glazing 64.2 m²
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 4 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

Built by Matto Luke Corp.

BASIX certificate

Energy score
89 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-80
Heating load
30 MJ/m² a year
Cooling load
21 MJ/m² a year
Bedrooms
4
Conditioned floor area
237.4 m²
Unconditioned floor area
10.5 m²
Site area
2,255 m²
Roof area
411 m²
Garden area
500 m²
Climate zone
NatHERS climate zone 15
Hot water
Gas instantaneous with a performance of 4 stars
Solar panels
3.3 kW
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 64.2 m², single glazing 64.2 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 1 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (polystyrene)
  • Garage floor: concrete slab on ground, waffle pod slab (polystyrene)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1764156S, issued 12 September 2024, from the council's DA documents.

Other certificates for this address

BASIX certificate, certificate 1739620S, issued 13 March 2024

BASIX certificate

Energy score
71 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
37 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
4
Conditioned floor area
167.5 m²
Unconditioned floor area
18.8 m²
Site area
2,082 m²
Roof area
338 m²
Garden area
1,533 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 21 to 25 STCs or better
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 24.9 m², single glazing 24.9 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (not specified)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1739620S, issued 13 March 2024, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.

Related