12 Red Gum Circuit Kew NSW 2439

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 57 against 40 for water.

Key features

Windows
22 windows and glazed doors: Timber A SG Clear; RESIDENTIAL SERIES 502/504 SLIDING WINDOW - SINGLE GLAZED; RESIDENTIAL SERIES 516 AWNING WINDOW- SINGLE GLAZED and 4 more types
Wall insulation
Fibreglass batts or roll
Roof and ceiling insulation
Roof Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.80, light colour
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
71 (target 70)
Water score
57 (target 40)
Materials score
-75
Heating load
32 MJ/m² a year
Cooling load
19 MJ/m² a year
Bedrooms
4
Conditioned floor area
157.4 m²
Unconditioned floor area
9 m²
Site area
532 m²
Roof area
274 m²
Garden area
255 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Fixtures
Showerheads 5 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 46.3 m², single glazing 15.6 m², double glazing 30.7 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • External garage wall: cavity brick; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
  • Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1860682S_03, issued 26 August 2026, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
Hero 4.1
Rated on
25 Aug 2026
Living room glazing by direction
N 7.6 m², E 13.7 m²
All glazing by direction
N 7.6 m², E 15.5 m², S 11.2 m², W 9.5 m²

Roof

  • Added insulation absorptance Roof Colour ATTIC-METAL-01: Pitched / Attic Metal Roof (Roofspace) & Flat PB Ceiling 1.80, light colour
  • FLAT-01: Flat Framed / Skillion Metal Roof & Flat PB Ceiling 1.80, light colour

Window types

  • TIM-001-01 W Timber A SG Clear: U-value 5.4, SHGC 0.56
  • AWS-001-005 RESIDENTIAL SERIES 502/504 SLIDING WINDOW - SINGLE GLAZED: U-value 4.6, SHGC 0.45
  • AWS-007-007 RESIDENTIAL SERIES 516 AWNING WINDOW- SINGLE GLAZED: U-value 4.9, SHGC 0.41
  • AWS-008-055 RESIDENTIAL SERIES 516 AWNING WINDOW- DOUBLE GLAZED: U-value 3.6, SHGC 0.41
  • AWS-013-048 RESIDENTIAL SERIES 541/542 SLIDING DOOR -DOUBLE GLAZED: U-value 3.2, SHGC 0.45
  • AWS-066-002 RESIDENTIAL SERIES 516 FIXED WINDOW - SINGLE GLAZED: U-value 3.9, SHGC 0.47
  • AWS-067-037 RES SERIES 516 FIXED WINDOW: U-value 2.4, SHGC 0.5

Window schedule

  • Bath, window AWS-066-002: 2,100 × 1,200 mm facing S
  • Bed 1, window AWS-001-005: 1,200 × 2,100 mm facing S
  • Bed 2, window AWS-001-005: 1,200 × 1,500 mm facing S
  • Bed 3, window AWS-001-005: 1,200 × 1,500 mm facing S
  • Bed 4, window AWS-001-005: 600 × 1,800 mm facing S
  • Bed 4, window AWS-001-005: 1,200 × 1,500 mm facing E
  • Ens., window AWS-001-005: 1,200 × 1,200 mm facing S
  • Ens., window AWS-007-007: 600 × 1,800 mm facing W
  • Entry, window TIM-001-01 W: 2,040 × 1,200 mm facing W
  • Entry, window AWS-066-002: 780 × 1,200 mm facing W
  • Kitchen, window AWS-008-055: 1,500 × 900 mm facing N
  • Kitchen, window AWS-008-055: 1,500 × 900 mm facing N
  • Kitchen, window AWS-067-037: 600 × 900 mm facing N
  • Kitchen, window AWS-067-037: 600 × 1,800 mm facing N
  • Kitchen, window AWS-008-055: 1,500 × 900 mm facing N
  • Kitchen, window AWS-008-055: 1,500 × 900 mm facing N
  • Kitchen, window AWS-067-037: 600 × 900 mm facing N
  • Kitchen, window AWS-013-048: 2,400 × 2,850 mm facing E
  • Kitchen, window AWS-013-048: 2,400 × 2,850 mm facing E
  • Multipose, window AWS-008-055: 700 × 2,400 mm facing W
  • Multipose, window AWS-008-055: 700 × 2,400 mm facing W
  • Multipose, window AWS-067-037: 700 × 2,400 mm facing W

Certificate HR-OE0MRR-02, issued 25 August 2026, from the council's DA documents.