12 Dixon Avenue Port Macquarie NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 12 kW of solar panels and a 4,000 litre rainwater tank. It beat its BASIX energy target, scoring 100 against 70.
Key features
- Windows
- Up to aluminium frames 73.4 m², timber frames 1.4 m², single glazing 7.1 m², double glazing 67.7 m²
- Wall insulation
- Fibreglass batts or roll; No added insulation
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 100 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -25
- Heating load
- 27 MJ/m² a year
- Cooling load
- 24 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 233.2 m²
- Unconditioned floor area
- 13.4 m²
- Site area
- 655 m²
- Roof area
- 267 m²
- Garden area
- 305 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Solar panels
- 12 kW
- Rainwater tank
- 4,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 73.4 m², timber frames 1.4 m², single glazing 7.1 m², double glazing 67.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 2 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 2 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 2 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: above habitable rooms or mezzanine, fibre cement; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, fibre cement; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: cavity brick; frame: no frame (no added insulation)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1835542S, issued 3 March 2026, from the council's DA documents.