Skip to main content

116 Diamond Drive Port Macquarie NSW 2444

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to a 3,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 73 against 70 for energy and 41 against 40 for water.

Key features

Windows
Up to aluminium frames 50.2 m², single glazing 44.5 m², double glazing 5.7 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil/sarking
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

Built by Pycon Homes & Constructions.

BASIX certificate

Energy score
73 (target 70)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-49
Heating load
31 MJ/m² a year
Cooling load
20 MJ/m² a year
Bedrooms
4
Conditioned floor area
166.8 m²
Unconditioned floor area
17.4 m²
Site area
681 m²
Roof area
265 m²
Garden area
394 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Rainwater tank
3,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Clothes line
Yes
Maximum glazing
aluminium frames 50.2 m², single glazing 44.5 m², double glazing 5.7 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 3.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: suspended floor above enclosed subfloor, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)

Certificate 1810433S, issued 27 August 2025, from the council's DA documents.

Is this your home? Ask us to remove these details.

What else should you know about this block?

Dudils finds house plans whose living areas face north on your block. Search your own block free at dudils.com.