North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
102 Greenmeadows Drive Port Macquarie NSW 2444
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 13 kW of solar panels and a 6,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 98 against 70 for energy and 51 against 40 for water.
Key features
- Windows
- Up to uPVC frames 106.4 m², double glazing 106.4 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: none
- Hot water
- Electric boosted solar with a performance of 26 to 30 STCs or better
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 98 (target 70)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Materials score
- -87
- Heating load
- 33 MJ/m² a year
- Cooling load
- 16 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 274.8 m²
- Unconditioned floor area
- 33.8 m²
- Site area
- 1,200 m²
- Roof area
- 405 m²
- Garden area
- 180 m²
- Climate zone
- NatHERS climate zone 15
- Hot water
- Electric boosted solar with a performance of 26 to 30 STCs or better
- Solar panels
- 13 kW
- Rainwater tank
- 6,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- uPVC frames 106.4 m², double glazing 106.4 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
- Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (expanding foam)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: AAC veneer; frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: framed (solid or reconstituted timber weatherboard); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External garage wall: AAC veneer; frame: timber - H2 treated softwood (no added insulation)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: none.)
Certificate 1777150S_03, issued 4 March 2025, from the council's DA documents.