Skip to main content

10 Galena Grove Lake Cathie NSW 2445

Finding the block on the map…

BASIX certificate and NatHERS rating

This home beat its BASIX energy target, scoring 72 against 70.

Key features

Windows
Up to aluminium frames 58.2 m², timber frames 0.5 m², double glazing 58.7 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

Built by McDonald Jones Homes.

BASIX certificate

Energy score
72 (target 70)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
26 MJ/m² a year
Cooling load
20 MJ/m² a year
Bedrooms
5
Conditioned floor area
318.4 m²
Unconditioned floor area
17.7 m²
Site area
2,650 m²
Roof area
491 m²
Garden area
450 m²
Climate zone
NatHERS climate zone 15
Hot water
Electric heat pump with a performance of 15 to 20 STCs or better
Fixtures
Showerheads 3 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Induction
Clothes line
Yes
Maximum glazing
aluminium frames 58.2 m², timber frames 0.5 m², double glazing 58.7 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.5 - 4.0

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: light steel frame. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: light steel frame (no added insulation)
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: plasterboard; frame: light steel frame (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: light steel frame (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, light steel frame (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1802806S, issued 4 July 2025, from the council's DA documents.