North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
821 The Northern Road Cranebrook NSW 2749
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 12 kW of solar panels and a 100,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 94 against 70 for energy and 51 against 40 for water.
Key features
- Windows
- Up to aluminium frames 86.9 m², timber frames 3.8 m², single glazing 67.3 m², double glazing 23.4 m²
- Wall insulation
- All external walls fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 94 (target 70)
- Water score
- 51 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 42 MJ/m² a year
- Cooling load
- 17 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 440.5 m²
- Unconditioned floor area
- 24.2 m²
- Site area
- 20,001 m²
- Roof area
- 776 m²
- Garden area
- 500 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Electric heat pump with a performance of 15 to 20 STCs or better
- Solar panels
- 12 kW
- Rainwater tank
- 100,000 litres
- Fixtures
- Showerheads 3 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 86.9 m², timber frames 3.8 m², single glazing 67.3 m², double glazing 23.4 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll
- External garage wall: brick veneer; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1815525S, issued 2 October 2025, from the council's DA documents.