63 Serrata Road Caddens NSW 2747

Finding the block on the map…

BASIX certificate and NatHERS rating

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 1,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 42 against 40 for water.

Key features

Windows
21 windows and glazed doors: Aluminium B SG Clear; Aluminium A SG Clear; 516 Al Awining Window DG 008_AGG PLUS Clr 4_12_4 and 5 more types
Wall insulation
R2.5
Roof and ceiling insulation
Ceiling R2.5, R7.0, roof FFE9V5MVI9-01 NatHERS Certificate 7 Star Rating as of 9 Oct 2025 Cont:Attic-Continuous 1.8, medium colour
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, non ducted (living area and bedroom)

Built by Inspections Plus.

BASIX certificate

Energy score
71 (target 70)
Water score
42 (target 40)
Thermal performance
Pass
Materials score
-27
Heating load
32 MJ/m² a year
Cooling load
27 MJ/m² a year
Bedrooms
5
Conditioned floor area
157.3 m²
Unconditioned floor area
14.1 m²
Site area
260 m²
Roof area
170 m²
Garden area
70 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Rainwater tank
1,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 37.3 m², single glazing 18.6 m², double glazing 18.7 m²

Heating

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
  • Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Floor: above habitable rooms or mezzanine, particle board; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
  • Floor: suspended floor above garage, particle board; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1811432S_02, issued 9 October 2025, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
FirstRate5: 5.5.5a (3.22)
Rated on
9 Oct 2025
Wall insulation
R2.5
Ceiling insulation
R2.5, R7.0
Floor insulation
R2.5
Living room glazing by direction
N 3.8 m², E 8.3 m², S 1.1 m²
All glazing by direction
N 11.6 m², E 12.1 m², S 4.4 m², W 9.8 m²

Roof

  • FFE9V5MVI9-01 NatHERS Certificate 7 Star Rating as of 9 Oct 2025 Cont:Attic-Continuous 1.8, medium colour

Window types

  • ALM-002-01 A Aluminium B SG Clear: U-value 6.7, SHGC 0.7
  • ALM-001-01 A Aluminium A SG Clear: U-value 6.7, SHGC 0.57
  • AWS-008-57 A 516 Al Awining Window DG 008_AGG PLUS Clr 4_12_4: U-value 3.44, SHGC 0.45
  • AWS-001-22 A 502/504 Al Sliding Window SG AGG 6EA: U-value 4.56, SHGC 0.61
  • AWS-003-86 A 502/504 Al Sliding Window DG 4-12-4ClimaTech: U-value 3.3, SHGC 0.51
  • AWS-013-54 A 541/542 Al Sliding Door DG 008_AGG PLUS Clr 4_12_4: U-value 2.97, SHGC 0.5
  • AWS-069-39 A RES SERIES 517 FIXED WINDOW DG 008_AGG PLUS Clr 4_12_4: U-value 2.53, SHGC 0.56
  • AWS-007-28 A 516 Al Awining Window SG 6ETClr: U-value 4.92, SHGC 0.54

Window schedule

  • Study, window AWS-008-57 A: 1,800 × 1,210 mm facing W
  • bed 5, window AWS-001-22 A: 1,030 × 1,810 mm facing N
  • Powder, window AWS-001-22 A: 600 × 1,210 mm facing N
  • Kitchen/Living/-Dining, window AWS-003-86 A: 1,800 × 2,170 mm facing E
  • Kitchen/Living/-Dining, window AWS-013-54 A: 2,100 × 1,810 mm facing N
  • Kitchen/Living/-Dining, window AWS-013-54 A: 2,100 × 2,110 mm facing E
  • Kitchen/Living/-Dining, window AWS-069-39 A: 600 × 1,810 mm facing S
  • Bed4, window AWS-001-22 A: 1,030 × 1,810 mm facing E
  • Upstairs Bath, window AWS-001-22 A: 1,030 × 1,570 mm facing S
  • Childs Retreat, window AWS-003-86 A: 600 × 1,810 mm facing S
  • ENS MasterBed, window AWS-001-22 A: 500 × 1,210 mm facing S
  • WIR MasterBed, window AWS-007-28 A: 1,800 × 1,950 mm facing W
  • WIR MasterBed, window ALM-002-01 A: 500 × 1,410 mm facing W
  • WIR MasterBed, window ALM-002-01 A: 500 × 200 mm facing W
  • MasterBed, window AWS-007-28 A: 600 × 1,810 mm facing W
  • MasterBed, window ALM-001-01 A: 600 × 1,810 mm facing W
  • MasterBed, window ALM-001-01 A: 600 × 1,810 mm facing W
  • Bed2, window AWS-001-22 A: 1,030 × 1,810 mm facing N
  • Bed3, window AWS-001-22 A: 1,030 × 1,804 mm facing E
  • WC, window AWS-001-22 A: 1,200 × 610 mm facing N
  • Upstairs Hallway, window AWS-069-39 A: 1,800 × 1,450 mm facing N

Certificate FFE9V5MVI9-01, issued 9 October 2025, from the council's DA documents. Verify this certificate

Is this your home? Ask us to remove these details.