BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 1,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 71 against 70.
Key features
- Windows
- 26 windows and glazed doors: 502/504 Al Sliding Window SG 638CP; 516 Al Awining Window SG 638CP; 541/542 Al Sliding Door SG 638CP and 2 more types
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R2.5, R6.0, roof Cont:Attic-Continuous 1.8, medium colour
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 71 (target 70)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 44 MJ/m² a year
- Cooling load
- 15 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 337.8 m²
- Unconditioned floor area
- 13 m²
- Site area
- 426 m²
- Roof area
- 298 m²
- Garden area
- 141 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 6 stars
- Rainwater tank
- 1,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 67 m², single glazing 67 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 4 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, plywood; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
- Floor: suspended floor above garage, plywood; frame: laminated veneer lumber (LVL) (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
- External garage wall: brick veneer; frame: timber - H2 treated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1826385S, issued 12 December 2025, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 10 Dec 2025
- Wall insulation
- R2.5
- Ceiling insulation
- R2.5, R6.0
- Floor insulation
- R2.5, R2.0
- Living room glazing by direction
- N 13.7 m², E 1.5 m², S 10.4 m², W 9.9 m²
- All glazing by direction
- N 21.2 m², E 9 m², S 17.6 m², W 19.2 m²
Roof
- Cont:Attic-Continuous 1.8, medium colour
Window types
- AWS-001-19 A 502/504 Al Sliding Window SG 638CP: U-value 4.52, SHGC 0.59
- AWS-007-19 A 516 Al Awining Window SG 638CP: U-value 4.9, SHGC 0.53
- AWS-011-18 A 541/542 Al Sliding Door SG 638CP: U-value 4.36, SHGC 0.59
- AWS-018-06 A 549 ED Al Entry Door SG 6.38CP: U-value 4.44, SHGC 0.35
- AWS-066-03 A RES SERIES 516 FIXED WINDOW SG 638ComPlsClr: U-value 3.91, SHGC 0.62
Window schedule
- Garage, window AWS-001-19 A: 600 × 1,810 mm facing E
- Media, window AWS-001-19 A: 600 × 3,300 mm facing E
- Pantry, window AWS-001-19 A: 600 × 2,170 mm facing E
- LDRY, window AWS-001-19 A: 600 × 1,570 mm facing E
- Bedroom 1, window AWS-001-19 A: 2,050 × 1,810 mm facing W
- ENS, window AWS-007-19 A: 2,050 × 610 mm facing W
- Study, window AWS-007-19 A: 2,050 × 610 mm facing W
- Kitchen/Living, window AWS-001-19 A: 2,050 × 1,570 mm facing N
- Kitchen/Living, window AWS-001-19 A: 2,050 × 1,570 mm facing N
- Kitchen/Living, window AWS-011-18 A: 2,410 × 2,675 mm facing W
- Kitchen/Living, window AWS-011-18 A: 2,400 × 3,010 mm facing N
- Kitchen/Living, window AWS-007-19 A: 2,050 × 820 mm facing W
- Kitchen/Living, window AWS-007-19 A: 2,050 × 850 mm facing W
- Living, window AWS-007-19 A: 2,050 × 1,810 mm facing S
- Bedroom 4, window AWS-001-19 A: 1,200 × 2,100 mm facing N
- Bath, window AWS-001-19 A: 860 × 1,570 mm facing W
- Bedroom 5, window AWS-001-19 A: 1,200 × 2,100 mm facing N
- ENS, window AWS-001-19 A: 860 × 850 mm facing E
- SHWR, window AWS-001-19 A: 600 × 1,210 mm facing E
- WC, window AWS-001-19 A: 860 × 850 mm facing E
- Bedroom Master, window AWS-011-18 A: 2,400 × 3,010 mm facing S
- Bedroom 3, window AWS-001-19 A: 860 × 2,100 mm facing W
- Rumpus, window AWS-007-19 A: 2,050 × 1,810 mm facing S
- Rumpus, window AWS-018-06 A: 2,340 × 620 mm facing E
- Rumpus, window AWS-066-03 A: 2,050 × 1,450 mm facing S
- Study Hallway, window AWS-001-19 A: 1,200 × 2,100 mm facing N
Certificate JVEC3PKCET, issued 10 December 2025, from the council's DA documents. Verify this certificate