28 Matthew Bell Way Jordan Springs NSW 2747
BASIX certificate and NatHERS rating
This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to 2 kW of solar panels and a 3,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor. It beat its BASIX energy target, scoring 79 against 70.
Key features
- Windows
- 26 windows and glazed doors: Aluminium B SG High Solar Gain Low-E; Aluminium A SG High Solar Gain Low-E; Sliding Door DG 016_AGG PRIME Gy 6_16_6
- Wall insulation
- R2.5
- Roof and ceiling insulation
- Ceiling R3.5, R7.0, roof Cont:Attic-Continuous 1.8, light colour
- Hot water
- Gas instantaneous with a performance of 4 stars
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 79 (target 70)
- Water score
- 40 (target 40)
- Materials score
- -71
- Heating load
- 40 MJ/m² a year
- Cooling load
- 19 MJ/m² a year
- Bedrooms
- 5
- Conditioned floor area
- 359.8 m²
- Unconditioned floor area
- 7.5 m²
- Site area
- 560 m²
- Roof area
- 277 m²
- Garden area
- 123 m²
- Climate zone
- NatHERS climate zone 28
- Hot water
- Gas instantaneous with a performance of 4 stars
- Solar panels
- 2 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 3 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 56.7 m², single glazing 35 m², double glazing 21.6 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - untreated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
- External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll+ foil/sarking
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1853424S, issued 27 June 2026, from the council's DA documents.
NatHERS certificate
- Star rating
- 7 stars
- Rated with
- FirstRate5: 5.5.5a (3.22)
- Rated on
- 27 Jun 2026
- Wall insulation
- R2.5
- Ceiling insulation
- R3.5, R7.0
- Floor insulation
- R2.5, R2.0, R3.5
- Living room glazing by direction
- N 3 m², E 7.2 m², S 3.1 m², W 14 m²
- All glazing by direction
- N 10.7 m², E 18.8 m², S 12.4 m², W 19.1 m²
Roof
- Cont:Attic-Continuous 1.8, light colour
- Cont:Attic-Continuous 1.8, medium colour
Window types
- ALM-002-03 A Aluminium B SG High Solar Gain Low-E: U-value 5.4, SHGC 0.58
- ALM-001-03 A Aluminium A SG High Solar Gain Low-E: U-value 5.4, SHGC 0.49
- ALU-005-30 A Sliding Door DG 016_AGG PRIME Gy 6_16_6: U-value 1.94, SHGC 0.29
Window schedule
- GF - Living /Dining /Kitchen, window ALM-002-03 A: 2,100 × 2,100 mm facing W
- GF - Living /Dining /Kitchen, window ALU-005-30 A: 2,400 × 4,000 mm facing W
- GF - Living /Dining /Kitchen, window ALM-002-03 A: 600 × 2,700 mm facing S
- GF - Living /Dining /Kitchen, window ALM-001-03 A: 2,100 × 710 mm facing N
- GF - Living /Dining /Kitchen, window ALM-001-03 A: 2,100 × 710 mm facing N
- GF - Theatre, window ALM-002-03 A: 1,500 × 2,100 mm facing N
- GF - Guest Bed, window ALM-001-03 A: 2,100 × 710 mm facing E
- GF - Guest Bed, window ALM-001-03 A: 2,100 × 710 mm facing E
- GF - ENS, window ALM-002-03 A: 600 × 1,210 mm facing S
- GF - B.Kitchen, window ALM-002-03 A: 600 × 2,400 mm facing S
- GF - Laundry, window ALM-002-03 A: 2,400 × 1,810 mm facing S
- FF - BED-3, window ALM-002-03 A: 1,200 × 1,810 mm facing W
- FF - BED-3, window ALM-002-03 A: 600 × 1,570 mm facing N
- FF - WIR-2, window ALM-001-03 A: 1,200 × 610 mm facing W
- FF - ENS-3, window ALM-002-03 A: 600 × 1,210 mm facing N
- FF - BED-4, window ALM-002-03 A: 1,200 × 1,810 mm facing N
- FF - BED-2, window ALM-002-03 A: 1,200 × 1,810 mm facing W
- FF - BED-2, window ALM-002-03 A: 600 × 1,570 mm facing S
- FF - ENS-2, window ALM-002-03 A: 600 × 1,200 mm facing S
- FF - ENS-M.BED, window ALM-002-03 A: 600 × 1,200 mm facing S
- FF - M.BED, window ALM-002-03 A: 2,100 × 890 mm facing S
- FF - M.BED, window ALM-002-03 A: 2,100 × 1,100 mm facing E
- FF - M.BED, window ALM-001-03 A: 2,100 × 710 mm facing E
- FF - M.BED, window ALU-005-30 A: 2,400 × 2,000 mm facing E
- FF - Upper Family, window ALU-005-30 A: 2,400 × 3,000 mm facing E
- FF - ENS-4, window ALM-002-03 A: 600 × 1,210 mm facing N
Certificate TERYY0CPP3, issued 27 June 2026, from the council's DA documents.