Skip to main content

2-10 Bowood Road Mount Vernon NSW 2178

Finding the block on the map…

BASIX certificate and NatHERS rating

This home's BASIX certificate commits it to 3 kW of solar panels and a 10,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 71 against 70 for energy and 41 against 40 for water.

Key features

Windows
Up to aluminium frames 40 m², single glazing 40 m²
Wall insulation
All external walls fibreglass batts or roll
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 6 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
71 (target 70)
Water score
41 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
31 MJ/m² a year
Cooling load
29 MJ/m² a year
Bedrooms
4
Conditioned floor area
819 m²
Unconditioned floor area
38 m²
Site area
13,649 m²
Roof area
1,449 m²
Garden area
60 m²
Climate zone
NatHERS climate zone 28
Hot water
Gas instantaneous with a performance of 6 stars
Solar panels
3 kW
Rainwater tank
10,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 40 m², single glazing 40 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)

Construction and insulation

  • Floor: concrete slab on ground, waffle pod slab (no added insulation)
  • Garage floor: concrete slab on ground, waffle pod slab (no added insulation)
  • External wall: brick veneer; frame: timber - untreated softwood. all external walls fibreglass batts or roll
  • External garage wall: brick veneer; frame: timber - untreated softwood (fibreglass batts or roll)
  • Internal wall shared with garage: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1787655S_03, issued 12 November 2025, from the council's DA documents.