North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
68 Arcadian Circuit Carlingford NSW 2118
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 20 kW of solar panels and a 3,000 litre rainwater tank. It beat its BASIX energy target, scoring 97 against 72.
Key features
- Windows
- Up to aluminium frames 141.7 m², double glazing 141.7 m²
- Wall insulation
- Rockwool batts, roll or pump-in; Polystyrene
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Electric heat pump with a performance of 41 to 45 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
BASIX certificate
- Energy score
- 97 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 23 MJ/m² a year
- Cooling load
- 7 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 395.3 m²
- Unconditioned floor area
- 55.6 m²
- Site area
- 818 m²
- Roof area
- 298 m²
- Garden area
- 312 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump with a performance of 41 to 45 STCs or better
- Solar panels
- 20 kW
- Rainwater tank
- 3,000 litres
- Fixtures
- Showerheads 4 star, toilets 5 star, kitchen taps 5 star, basin taps 5 star
- LED lighting
- Yes
- Cooktop
- Gas
- Maximum glazing
- aluminium frames 141.7 m², double glazing 141.7 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
- Bedroom: 1-phase airconditioning - ducted; Energy rating: 3 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - untreated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - untreated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, concrete - suspended; frame: timber - untreated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: concrete block/plasterboard; frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- External wall: cavity brick; frame: no frame (polystyrene)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (rockwool batts, roll or pump-in)
- External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
- Internal wall: block with low cement content and reconstituted sawdust; frame: no frame (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: flat ceiling / flat roof, framed - metal roof, timber - untreated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1752257S, issued 19 June 2024, from the council's DA documents.