North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
96 Hilma Street Collaroy Plateau NSW 2097
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 3 kW of solar panels and a 3,500 litre rainwater tank. It beat its BASIX energy target, scoring 73 against 72.
Key features
- Windows
- Up to aluminium frames 78.7 m², single glazing 2.7 m², double glazing 76 m²
- Wall insulation
- Polystyrene+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 5 stars
- Air conditioning and heating
- 3-phase airconditioning (living area and bedroom)
BASIX certificate
- Energy score
- 73 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -100
- Heating load
- 22 MJ/m² a year
- Cooling load
- 8 MJ/m² a year
- Bedrooms
- 6
- Conditioned floor area
- 302.2 m²
- Unconditioned floor area
- 4.8 m²
- Site area
- 417 m²
- Roof area
- 185 m²
- Garden area
- 174 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 5 stars
- Solar panels
- 3 kW
- Rainwater tank
- 3,500 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 4 star
- LED lighting
- Yes
- Cooktop
- Gas
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 78.7 m², single glazing 2.7 m², double glazing 76 m²
Heating
- Living area: 3-phase airconditioning; Energy rating: EER < 2.5
- Bedroom: 3-phase airconditioning; Energy rating: EER < 2.5
Cooling
- Living area: 3-phase airconditioning; Energy rating: EER < 2.5
- Bedroom: 3-phase airconditioning; Energy rating: EER < 2.5
Construction and insulation
- Floor: concrete slab on ground, conventional slab (polystyrene)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Floor: suspended floor above garage, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Garage floor: concrete slab on ground (polystyrene)
- External wall: concrete block/plasterboard; frame: no frame (polystyrene+ foil/sarking)
- External wall: cavity brick; frame: no frame (polystyrene+ foil/sarking)
- External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
- Internal wall: single skin masonry; frame: no frame (no added insulation)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1792013S, issued 15 April 2025, from the council's DA documents.