North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
8 Quarter Sessions Road Church Point NSW 2105
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to a 2,000 litre rainwater tank. It beat its BASIX energy and water targets, scoring 73 against 72 for energy and 43 against 40 for water.
Key features
- Windows
- Up to aluminium frames 80.9 m², single glazing 43.8 m², double glazing 37.1 m²
- Wall insulation
- Fibreglass batts or roll
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil backed blanket
- Hot water
- Electric heat pump
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
BASIX certificate
- Energy score
- 73 (target 72)
- Water score
- 43 (target 40)
- Thermal performance
- Pass
- Materials score
- -32
- Heating load
- 19 MJ/m² a year
- Cooling load
- 11 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 214.1 m²
- Unconditioned floor area
- 21.4 m²
- Site area
- 1,023 m²
- Roof area
- 110 m²
- Garden area
- 750 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Electric heat pump
- Rainwater tank
- 2,000 litres
- Fixtures
- Showerheads 4 star, toilets 6 star, kitchen taps 6 star, basin taps 6 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 80.9 m², single glazing 43.8 m², double glazing 37.1 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: 2.5 star (average zone)
Construction and insulation
- Floor: concrete slab on ground, conventional slab (no added insulation)
- Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
- Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
- Floor: suspended floor above garage, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
- Garage floor: concrete slab on ground (no added insulation)
- External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood (fibreglass batts or roll)
- External wall: concrete block/plasterboard; frame: no frame (fibreglass batts or roll)
- External garage wall: concrete block/plasterboard; frame: no frame (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (fibreglass batts or roll)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)
Certificate 1833546S_02, issued 24 February 2026, from the council's DA documents.