Skip to main content

77 Wimbledon Avenue North Narrabeen NSW 2101

BASIX certificate and NatHERS rating

Finding the block on the map…

This home has a NatHERS rating of 7 stars out of 10. Its BASIX certificate commits it to a 2,000 litre rainwater tank. Its NatHERS certificate lists insulation in the external walls, ceiling and floor.

Key features

Windows
41 windows and glazed doors: VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La
Wall insulation
R1
Roof and ceiling insulation
Ceiling R3, R6, R2.5, roof Waterproofing Membrane No Added Insulation, No air Gap, light colour
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
3-phase airconditioning (living area and bedroom)

BASIX certificate

Energy score
72 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-100
Heating load
13 MJ/m² a year
Cooling load
16 MJ/m² a year
Bedrooms
5
Conditioned floor area
310.7 m²
Unconditioned floor area
5.8 m²
Site area
626 m²
Roof area
205 m²
Garden area
348 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Rainwater tank
2,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 5 star, basin taps 5 star
LED lighting
Yes
Cooktop
Gas
Clothes line
Yes
Maximum glazing
aluminium frames 190.5 m², single glazing 3.2 m², double glazing 187.3 m²

Heating

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5
  • Bedroom: 3-phase airconditioning; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: suspended floor above open subfloor, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Floor: above habitable rooms or mezzanine, concrete - suspended; frame: timber - H2 treated softwood (no added insulation)
  • Floor: suspended floor above garage, concrete - suspended; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete - suspended; frame: no frame (fibreglass batts or roll)
  • External wall: cavity brick; frame: no frame. all external walls fibreglass batts or roll
  • External garage wall: cavity brick; frame: no frame (no added insulation)
  • Internal wall: single skin masonry; frame: no frame (no added insulation)
  • Ceiling and roof: flat ceiling / flat roof, concrete - plasterboard internal, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1769978S, issued 23 October 2024, from the council's DA documents.

NatHERS certificate

Star rating
7 stars
Rated with
BERS Pro v5.2.2 (3.23)
Rated on
23 Oct 2024
Wall insulation
R1
Ceiling insulation
R3, R6, R2.5
Floor insulation
R1, R2.5, R2, R3
Living room glazing by direction
N 7.2 m², E 6.6 m², S 7.8 m², W 32.9 m²
All glazing by direction
N 45.6 m², E 33.4 m², S 42.6 m², W 70 m²

Roof

  • Waterproofing Membrane No Added Insulation, No air Gap, light colour
  • Corrugated Iron Timber Frame Bulk, Reflective Side Down, Anti-glare Up R2, light colour

Window types

  • VEL-011-01 W VELUX FS - Fixed Skylight DG 3mm LoE 366 / 8.5mm Argon Gap / 5.36mm Clear La: U-value 2.6, SHGC 0.24

Window schedule

  • Garage ATB-006-03 B W18: 3,500 × 1,000 mm facing S
  • Bedroom 1 ATB-006-03 B W39: 2,300 × 2,500 mm facing W
  • Bedroom 1 ATB-005-03 B W14: 2,300 × 600 mm facing N
  • Bedroom 1 ATB-005-03 B W15: 2,300 × 600 mm facing N
  • Bedroom 1 ATB-006-03 B W32: 2,300 × 1,800 mm facing E
  • Bedroom 2 ATB-006-03 B W31: 2,300 × 2,000 mm facing E
  • Bedroom 2 ATB-005-03 B W26: 2,300 × 600 mm facing S
  • Bedroom 2 ATB-005-03 B W27: 2,300 × 600 mm facing S
  • Master Bed 1 ATB-005-03 B W6: 2,300 × 600 mm facing N
  • Master Bed 1 ATB-005-03 B W7: 2,300 × 600 mm facing N
  • Master Bed 1 ATB-006-03 B W66: 2,300 × 2,500 mm facing E
  • Master Bed 1 ATB-006-03 B: 2,700 × 4,400 mm facing W
  • Master Bed 2 ATB-005-03 B W22: 2,300 × 600 mm facing S
  • Master Bed 2 ATB-005-03 B W23: 2,300 × 600 mm facing S
  • Master Bed 2 ATB-006-03 B W37: 2,700 × 4,900 mm facing W
  • ENS Bed 1 ATB-005-03 B W34: 2,300 × 700 mm facing E
  • ENS Bed 2 ATB-005-03 B W33: 2,300 × 700 mm facing E
  • Master WIR ATB-006-03 B W67: 2,300 × 500 mm facing N
  • Master Bath ATB-006-04 B W24: 2,700 × 2,000 mm facing S
  • Guestroom ATB-006-03 B W42: 3,000 × 600 mm facing N
  • Guestroom ATB-006-03 B W43: 800 × 2,000 mm facing N
  • Guestroom ATB-006-03 B W29: 2,900 × 1,300 mm facing E
  • Guestroom ATB-006-03 B W61: 2,900 × 400 mm facing E
  • ENS Guest ATB-006-03 B W28: 2,900 × 400 mm facing E
  • Powder ATB-006-03 B W17: 3,000 × 1,000 mm facing S
  • Kitchen/Living ATB-006-03 B W49: 2,700 × 600 mm facing N
  • Kitchen/Living ATB-006-03 B W46: 2,700 × 600 mm facing N
  • Kitchen/Living ATB-006-03 B W50: 3,000 × 2,200 mm facing E
  • Kitchen/Living ATB-006-03 B W57: 600 × 4,050 mm facing S
  • Kitchen/Living ALS-114-017-004 W65: 3,000 × 10,950 mm facing W
  • Kitchen/Living A&L-001-004-001 S7: 300 × 6,600 mm facing N
  • Kitchen/Living ATB-006-03 B S8: 300 × 6,600 mm facing N
  • Hallway GF ATB-006-03 B W55: 3,500 × 2,800 mm facing S
  • Hallway GF ATB-005-03 B W53: 3,000 × 5,200 mm facing N
  • Hallway GF ATB-006-03 B W54: 3,000 × 1,100 mm facing W
  • Hallway L1 ATB-006-03 B W58: 2,700 × 1,100 mm facing W
  • Hallway L1 ATB-006-03 B W59: 2,700 × 4,200 mm facing N
  • Hallway L1 ATB-006-03 B W60: 2,700 × 1,100 mm facing E
  • Hallway L1 ATB-006-03 B W48: 2,300 × 600 mm facing N
  • Hallway L1 ATB-006-03 B W45: 2,700 × 2,800 mm facing S
  • Wet Kitchen ATB-006-03 B W63: 3,000 × 1,800 mm facing S

Certificate 0009930025, issued 23 October 2024, from the council's DA documents. Verify this certificate