North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
71 Whistler Street Manly NSW 2095
BASIX certificate and NatHERS rating
Finding the block on the map…
This home's BASIX certificate commits it to 3.5 kW of solar panels and a 1,500 litre rainwater tank. It beat its BASIX energy and water targets, scoring 93 against 72 for energy and 41 against 40 for water.
Key features
- Windows
- Up to aluminium frames 32.6 m², timber frames 32.9 m², double glazing 65.5 m²
- Wall insulation
- Not specified+ foil/sarking; Fibreglass batts or roll+ foil/sarking
- Roof and ceiling insulation
- Ceiling: fibreglass batts or roll; roof: foil/sarking
- Hot water
- Gas instantaneous with a performance of 6 stars
- Air conditioning and heating
- 1-phase airconditioning, non ducted (living area and bedroom)
BASIX certificate
- Energy score
- 93 (target 72)
- Water score
- 41 (target 40)
- Thermal performance
- Pass
- Materials score
- 1
- Heating load
- 17 MJ/m² a year
- Cooling load
- 13 MJ/m² a year
- Bedrooms
- 3
- Conditioned floor area
- 137.9 m²
- Unconditioned floor area
- 17.8 m²
- Site area
- 174 m²
- Roof area
- 106 m²
- Garden area
- 50 m²
- Climate zone
- NatHERS climate zone 56
- Hot water
- Gas instantaneous with a performance of 6 stars
- Solar panels
- 3.5 kW
- Rainwater tank
- 1,500 litres
- Fixtures
- Showerheads 4 star, toilets 3 star, kitchen taps 3 star, basin taps 3 star
- LED lighting
- Yes
- Cooktop
- Induction
- Clothes line
- Yes
- Maximum glazing
- aluminium frames 32.6 m², timber frames 32.9 m², double glazing 65.5 m²
Heating
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - non ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: suspended floor above enclosed subfloor, concrete - suspended; frame: no frame (fibreglass batts or roll)
- Garage floor: concrete - suspended; frame: no frame (fibreglass batts or roll)
- External wall: concrete block/plasterboard; frame: timber - untreated softwood (not specified+ foil/sarking)
- External wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- External garage wall: framed (fibre cement sheet or boards); frame: timber - untreated softwood (fibreglass batts or roll+ foil/sarking)
- Internal wall: plasterboard; frame: timber - untreated softwood (fibreglass batts or roll)
- Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
- Ceiling and roof: raked ceiling / pitched or skillion roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil/sarking.)
Certificate 1737110S, issued 23 February 2024, from the council's DA documents.