North facing house plans that fit your block
Home report
Saving this home report as a PDF is free with a Dudils account. Sign in at dudils.com, then press Save as PDF at the top of your report.
58 Oliver Street Freshwater NSW 2096
Finding the block on the map…
BASIX certificate and NatHERS rating
This home's BASIX certificate commits it to 2 kW of solar panels and a 1,000 litre rainwater tank. It beat its BASIX energy target, scoring 88 against 72.
Key features
- Windows
- Up to timber frames 58 m², single glazing 25 m², double glazing 33 m²
- Wall insulation
- All external walls rockwool batts, roll or pump-in
- Roof and ceiling insulation
- Ceiling: rockwool batts, roll or pump-in; roof: foil/sarking
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Air conditioning and heating
- 1-phase airconditioning, ducted (living area and bedroom)
Built by Allcastle Homes.
BASIX certificate
- Energy score
- 88 (target 72)
- Water score
- 40 (target 40)
- Thermal performance
- Pass
- Materials score
- -21
- Heating load
- 16 MJ/m² a year
- Cooling load
- 13 MJ/m² a year
- Bedrooms
- 4
- Conditioned floor area
- 185 m²
- Unconditioned floor area
- 17 m²
- Site area
- 399 m²
- Roof area
- 165 m²
- Garden area
- 158 m²
- Climate zone
- NatHERS climate zone 1
- Hot water
- Electric heat pump with a performance of 21 to 25 STCs or better
- Solar panels
- 2 kW
- Rainwater tank
- 1,000 litres
- Fixtures
- Showerheads 4 star, toilets 4 star, kitchen taps 4 star, basin taps 6 star
- LED lighting
- Yes
- Clothes line
- Yes
- Maximum glazing
- timber frames 58 m², single glazing 25 m², double glazing 33 m²
Heating
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Cooling
- Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
- Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
Construction and insulation
- Floor: concrete slab on ground, waffle pod slab (no added insulation)
- Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
- External wall: brick veneer; frame: timber - H2 treated softwood. all external walls rockwool batts, roll or pump-in
- Internal wall: plasterboard; frame: timber - H2 treated softwood (rockwool batts, roll or pump-in)
- Internal wall: plasterboard; frame: timber - H2 treated softwood (no added insulation)
- Ceiling and roof: flat ceiling / pitched roof, framed - concrete tiles , timber - H2 treated softwood (ceiling: rockwool batts, roll or pump-in; roof: foil/sarking.)
Certificate 1780331S, issued 20 January 2025, from the council's DA documents.
Is this your home? Ask us to remove these details.