Skip to main content

48 Park Street Narrabeen NSW 2101

BASIX certificate and NatHERS rating

Finding the block on the map…

This home's BASIX certificate commits it to 3 kW of solar panels and a 5,000 litre rainwater tank. It beat its BASIX energy target, scoring 73 against 72.

Key features

Windows
Up to uPVC frames 109 m², double glazing 109 m²
Wall insulation
All external walls fibreglass batts or roll+ foil/sarking
Roof and ceiling insulation
Ceiling: fibreglass batts or roll; roof: foil backed blanket
Hot water
Gas instantaneous with a performance of 5 stars
Air conditioning and heating
1-phase airconditioning, ducted (living area and bedroom)

BASIX certificate

Energy score
73 (target 72)
Water score
40 (target 40)
Thermal performance
Pass
Materials score
-25
Heating load
17 MJ/m² a year
Cooling load
13 MJ/m² a year
Bedrooms
4
Conditioned floor area
303 m²
Unconditioned floor area
12 m²
Site area
699 m²
Roof area
235 m²
Garden area
317 m²
Climate zone
NatHERS climate zone 56
Hot water
Gas instantaneous with a performance of 5 stars
Solar panels
3 kW
Rainwater tank
5,000 litres
Fixtures
Showerheads 4 star, toilets 4 star, kitchen taps 3 star, basin taps 3 star
LED lighting
Yes
Cooktop
Gas
Maximum glazing
uPVC frames 109 m², double glazing 109 m²

Heating

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Cooling

  • Living area: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5
  • Bedroom: 1-phase airconditioning - ducted; Energy rating: EER 3.0 - 3.5

Construction and insulation

  • Floor: concrete slab on ground, conventional slab (foil-foam composite board)
  • Floor: above habitable rooms or mezzanine, particle board; frame: timber - H2 treated softwood (fibreglass batts or roll)
  • Garage floor: concrete slab on ground (no added insulation)
  • External wall: framed (fibre cement sheet or boards); frame: timber - H2 treated softwood. all external walls fibreglass batts or roll+ foil/sarking
  • Internal wall: plasterboard; frame: timber - untreated softwood (no added insulation)
  • Ceiling and roof: flat ceiling / pitched roof, framed - metal roof, timber - H2 treated softwood (ceiling: fibreglass batts or roll; roof: foil backed blanket.)

Certificate 1793591S_02, issued 19 August 2025, from the council's DA documents.